verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-10 FRL Unit (GC30010LNW)

The AirTAC AirTAC GC300-10 FRL Unit (GC30010LNW) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$82.02 $87.75Save 6% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-10 FRL Unit (GC30010LNW)

The AirTAC GC series is a three-unit F.R.L.: separate air filter, pressure regulator and lubricator that together remove water and particulate, hold a set downstream pressure and add oil-mist lubrication to compressed air. This GC30010LNW is the size 300 configuration with PT3/8 ports, the low-pressure (L) regulator type, a differential-pressure drain on the filter bowl, the fine 5 um (W) filter element and no gauge. Bowls at size 300 are polycarbonate; maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The G series is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, plus automatic or manual drains, the 40 um standard element, gauges in MPa, psi or bar scales, G or NPT threads and an optional bracket. AirTAC publishes flow for the G series as curves rather than one rated figure, so we confirm flow and datasheet details for your application on request.

AirTAC GC300-10 FRL Unit (GC30010LNW) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010LNW)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010LNW)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010LNW) Is Used

science

Laboratory automation air supply

Conditioning air to pick-and-place modules and small test-rig actuators in a lab cell, where the 5 um element is chosen to keep finer particles away from compact directional valves.

view_module

Electronics assembly cells

Feeding screwdriver feeders, grippers and small clamps on an electronics assembly line with filtered, regulated and lubricated air at a low set pressure.

precision_manufacturing

Small-parts machining feeders

Running the air-driven part feeders and ejection cylinders on a secondary-operation machining station, with the bowl draining by differential pressure between checks.

Is the AirTAC GC300-10 FRL Unit (GC30010LNW) the Right Station?

Size 300 with PT3/8 ports is the mid-range step; move to size 400 or 600 when the demand outgrows it or to size 200 for light duty. The W at the end of the code selects the fine 5 um element instead of the 40 um standard: choose 5 um where downstream valves, cylinders or instruments are sensitive to finer contamination, and stay at 40 um where coarse water and particle removal is enough. The L marks the low-pressure regulator type; we confirm its adjustment range against the datasheet before you order.

As on any GC set you can also choose automatic (A) or manual (M) drain instead of the differential-pressure drain fitted here, a gauge in embedded square or external round form with MPa, psi or bar scales (this build has none), G (BSPP) or NPT threads in place of PT, and an optional bracket. Flow is published as curves rather than one rated figure, so ask us to confirm sizing against the application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010LNW) FAQ

AirTAC does not publish a single rated flow figure for the GC series; capacity is given as selection curves in the datasheet. Tell us your line pressure and air demand and we will confirm whether this size 300 set suits the job, or whether 200, 400 or 600 is the better fit, before you order.

The W in GC30010LNW selects the fine 5 um element in place of the 40 um standard. Use 40 um for general plant air where coarse water and particle removal is the job; choose 5 um where downstream valves, cylinders or instruments are sensitive to finer contamination. Both fit the same size 300 body, so the choice can be changed on later orders.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010LNW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30010LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.