verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015C1K)

The AirTAC AirTAC GC300-15 FRL Unit (GC30015C1K) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$99.03 $105.17Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-15 FRL Unit (GC30015C1K)

GC30015C1K is the three-piece AirTAC G-series F.R.L. combination - separate filter, regulator and lubricator in size 300 with PT1/2 ports - with the K reverse/check valve fitted and the round external gauge on MPa scale. The filter runs the standard 40 um element, the regulator holds 0.15-0.9 MPa (20-130 psi) downstream, the lubricator mists oil into the outgoing air, and the check valve blocks backflow through the unit. Bowls are polycarbonate on this size with the default differential-pressure drain.

This is a genuine AirTAC part. The same combination is available across G-series sizes 200 to 600, ports 1/8 in. to 1 in., with 40 um or 5 um elements, automatic, manual or differential-pressure drains, square or round gauges in MPa, psi or bar, and the check-valve option. Medium is compressed air only, max working pressure 1.0 MPa (145 psi), operating temperature -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure; we confirm datasheet figures on request.

AirTAC GC300-15 FRL Unit (GC30015C1K) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015C1K)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015C1K)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015C1K) Is Used

shield

Safety-monitoring clamp circuits

Supplying hold-and-clamp cylinders on a press or welding fixture, where the check valve helps the regulated circuit stay isolated from upstream venting while the gauge shows the standing pressure.

engineering

Hydraulic power-unit air backup

Conditioning the pneumatic pilot and accumulator-charge air on a hydraulic power unit, with lubricated air for pilot valves and a visible MPa reading for maintenance rounds.

local_shipping

Trailer dock and door actuators

Feeding powered dock-leveler and door actuators at a loading bay, with the check valve guarding against backflow when the bay air supply is shut off between shifts.

Is the AirTAC GC300-15 FRL Unit (GC30015C1K) the Right Station?

Pick this code when you want the readable round MPa gauge of the C1 configuration plus the K check valve against backflow - useful where downstream circuits must hold if the upstream side is vented. Size 300 with PT1/2 ports suits 1/2 in. machine and cell mains; because no single rated flow is published, have us check the flow curve against your demand first. The differential-pressure drain is the default here; automatic (A) or manual (M, 0.05-0.9 MPa range) are the other choices. The 40 um element is the standard grade, with 5 um (W) for finer protection. Gauge scale is MPa; psi or bar scales and the embedded square gauge exist in the series. PT thread is standard, G (BSPP) and NPT are order options; brackets included.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015C1K) FAQ

AirTAC publishes GC300 series flow as performance curves, not as a single rated figure, so we do not state a number here. Share your line pressure and required downstream flow and we will confirm sizing from the datasheet on request before you order.

Only the K option: a reverse/check valve is fitted, so downstream air cannot flow back through the unit when upstream pressure is lost or vented. Filter grade (40 um), drain type (differential-pressure), gauge (round, MPa), ports (PT1/2) and regulator range are otherwise the same.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015C1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015C1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.