AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015LN)

The AirTAC AirTAC GC300-15 FRL Unit (GC30015LN) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$82.02 $87.75Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-15 FRL Unit (GC30015LN)

GC30015LN is a three-piece AirTAC G-series F.R.L. combination supplied without a gauge: the N in the code deletes the regulator gauge. You still get the full three functions - a separate filter with the standard 40 um element and a differential-pressure drain bowl, a low-pressure type regulator (the L suffix), and a lubricator for oil-mist service. The 300 size is fitted with 1/2 inch ports in PT thread as standard.

This is a genuine AirTAC part supplied for the US market. The G-series offers the 200/300/400/600 sizes from 1/8 to 1 inch ports, G (BSPP) and NPT thread options, the 5 um (W) filter grade, automatic or manual drain choices, and versions with an embedded square or external round gauge in MPa, psi or bar scales. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing on request.

AirTAC GC300-15 FRL Unit (GC30015LN) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015LN)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015LN)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015LN) Is Used

handyman

Maintenance shop air drop

A wall-mounted F.R.L. at a maintenance drop: filtered, pressure-set and lubricated air for impact tools, air ratchets and blow-off work, with pressure read on the shop's existing gauge.

factory

Woodworking machine feed

Conditions the air feeding hold-downs and dust-gate cylinders on a saw or router line, where the panel already carries its own pressure indication so the unit is ordered without a gauge.

local_shipping

Truck and trailer service bay

Point-of-use preparation of shop air for brake-cage work and air-tool service on commercial vehicles, with the regulator set locally and monitored on the bay's master gauge.

Is the AirTAC GC300-15 FRL Unit (GC30015LN) the Right Station?

The LN configuration suits panels where pressure is read on a separate instrument or where no local indication is wanted; if you later need a gauge, the F1 square MPa version (GC30015LF1) is the same set with the gauge fitted. The 300 size gives you 1/2 inch PT ports; the 200/400/600 sizes cover other port steps and we confirm flow against the published curves before you order. Drain is differential-pressure as standard, with automatic (A) and manual (M) options; filtration is the standard 40 um element, with 5 um available as the W suffix. The L suffix marks the low-pressure regulator type - confirm its set-point range from the datasheet with us. G (BSPP) and NPT threads are catalogue options to the standard PT.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015LN) FAQ

AirTAC publishes G-series flow as performance curves rather than one rated number, so we do not quote a figure on the page. Share your line pressure and downstream air demand and we will confirm the correct size from the datasheet on request.

The N in the code deletes the regulator gauge. If you want local pressure indication, GC30015LF1 is the same three-unit set with an embedded square MPa gauge; external round gauges and psi or bar scales are also catalogue options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015LN)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015LN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.