verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015LNW)

The AirTAC AirTAC GC300-15 FRL Unit (GC30015LNW) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$82.02 $87.75Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-15 FRL Unit (GC30015LNW)

GC30015LNW combines two decode choices in one AirTAC G-series set: the W suffix specifies the fine 5 um filter element, and the N suffix deletes the regulator gauge. You still receive all three functions - filter, low-pressure type regulator (the L suffix) and lubricator - as separate bodies in one F.R.L. combination. The filter bowl drains by differential pressure, and the 300 size carries 1/2 inch ports in PT thread as standard.

This is a genuine AirTAC part distributed for the US market. Within the G-series you can select the 200/300/400/600 sizes from 1/8 to 1 inch ports, G (BSPP) or NPT thread, 40 um or 5 um filtration, automatic or manual drain in place of the differential-pressure bowl, and gauge versions in MPa, psi or bar scales if local indication is wanted. Rated flow is published as curves rather than a single figure, so we confirm the datasheet and sizing on request.

AirTAC GC300-15 FRL Unit (GC30015LNW) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015LNW)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015LNW)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015LNW) Is Used

science

Instrument air for test rigs

Fine-filtered, regulated and lubricated air for pneumatic functions on a test bench, where pressure is monitored on the rig's own transducer so the F.R.L. is ordered without a gauge.

precision_manufacturing

Clean air to assembly actuators

Supplies conditioned air to small-bore cylinders and air fingers on an electronics or small-parts assembly station, with the 5 um element protecting the fine control valves downstream.

valve

Process valve actuation panel

Prepares the pilot and actuation air for automated process valves on a skid, keeping condensate and fine particulate out of the positioners while the panel's own indicator shows the set pressure.

Is the AirTAC GC300-15 FRL Unit (GC30015LNW) the Right Station?

Pick this configuration when you need fine 5 um filtration, no local gauge, and 1/2 inch PT ports in the 300 size; if you later want pressure indication, the gauge-fitted and round-gauge versions are catalogue alternatives. The other port steps (200/400/600) cover 1/8 to 1 inch circuits, and we confirm flow against the published curves before ordering. Drain is differential-pressure as standard, with automatic (A) and manual (M) options available. The L suffix marks the low-pressure regulator type, so confirm its set-point range from the datasheet with us. PT is the standard thread; G (BSPP) and NPT are orderable thread options.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015LNW) FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated number, so we do not state a figure here. Give us your line pressure, downstream demand and acceptable pressure drop and we will confirm the sizing from the datasheet on request.

GC is the three-piece F.R.L. set (filter, regulator, lubricator), 300 is the size with PT1/2 ports, L is the low-pressure regulator type, N means no gauge is fitted, W specifies the 5 um filter grade, and the drain is the differential-pressure type as standard.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015LNW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.