verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015MLC1W)

The AirTAC AirTAC GC300-15 FRL Unit (GC30015MLC1W) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$87.68 $93.54Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-15 FRL Unit (GC30015MLC1W)

The GC30015MLC1W is a three-piece AirTAC G-series F.R.L. combination: a separate filter, regulator and lubricator assembled as one set. It removes water and particulate from compressed air, holds a steady downstream pressure and meters oil mist to the equipment it feeds. This configuration is size 300 with PT1/2 ports, a manual drain on the filter bowl, a fine 5 um filter element, the low-pressure regulator type and a round external gauge on an MPa scale. Maximum working pressure is 1.0 MPa (145 psi), and the 300-size bowls on the filter and lubricator are polycarbonate.

This is a genuine AirTAC part from the G series, which spans sizes 200, 300, 400 and 600 with a choice of ports, threads, drains, filter grades, gauges and regulator types. Rated flow is published as curves rather than a single figure, so ask us and we will confirm sizing and datasheet details for your application on request.

AirTAC GC300-15 FRL Unit (GC30015MLC1W) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015MLC1W)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015MLC1W)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015MLC1W) Is Used

settings_input_component

Blister packaging sealing heads

Feeds the seal cylinders and vacuum generators on a pharmaceutical blister line, giving the sealing station filtered, regulated and lubricated air at the modest settings those heads run.

valve

Bottling line filler actuators

Supplies the grippers and gate valves on a rotary bottle filler; the 5 um element helps keep water and fine debris out of the filler's compact valve stack.

view_module

Carton erector clamp circuit

Powers the clamp and flap-fold cylinders on a case erector at the head of a packing line, with oil mist conditioning the cylinder seals shift after shift.

Is the AirTAC GC300-15 FRL Unit (GC30015MLC1W) the Right Station?

Size 300 with a 1/2 in port suits circuits whose demand sits above the 1/4-3/8 in band; step down to size 200 or up to sizes 400/600 as your port and flow curve require. This set uses a manual drain, so an operator opens the bowl drain during routine checks; automatic or differential-pressure drain codes are available if you want condensate removal without that step. The W code selects the 5 um element over the standard 40 um. The L code selects the low-pressure regulator type with a manual-drain adjustment starting from 0.05 MPa - confirm the low-pressure ceiling with us before ordering. PT is the standard thread and G (BSPP) or NPT are catalogue options to order; here the gauge is a round external unit on the MPa scale, with psi or bar scales also available.

Because rated flow is published only as curves, not a single number, send us your demand profile and we will confirm this model is correctly sized before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015MLC1W) FAQ

AirTAC publishes flow for the GC series as curves rather than one headline figure, so quoting a single rated number here would be guesswork. Tell us your line demand and we will confirm the sizing from the datasheet on request.

The L code selects the low-pressure regulator variant, which is limited to lower settings than the standard type and suits circuits that never call for high pressure. Adjustment on this manual-drain set starts from the 0.05 MPa floor; confirm the exact ceiling with us before ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015MLC1W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015MLC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.