AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010C1WK)

The AirTAC AirTAC GC400-10 FRL Unit (GC40010C1WK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$135.35 $142.39Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-10 FRL Unit (GC40010C1WK)

The AirTAC GC series combines a separate air filter, pressure regulator and oil-mist lubricator into one three-piece F.R.L. set. The GC40010C1WK serves 3/8 in PT ports in size 400, uses the fine 5 um filter element (W) with the default differential-pressure drain, carries the external round gauge on an MPa scale, and is fitted with a reverse (check) valve (K) so downstream pressure is held if the upstream supply drops.

This is a genuine AirTAC part. The series spans sizes 200, 300, 400 and 600 with PT, G (BSPP) or NPT threads, 40 um or 5 um filtration, and MPa, psi or bar gauge scales. Maximum working pressure is 1.0 MPa (145 psi) with a -5 to 70 C, non-freezing temperature range. Flow is published as curves, not a single rating, so ask us to confirm sizing and datasheet figures on request.

AirTAC GC400-10 FRL Unit (GC40010C1WK) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010C1WK)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010C1WK)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010C1WK) Is Used

precision_manufacturing

Robotic Gripper Circuit

Condition the air feeding a six-axis robot's pneumatic gripper on a pick-and-place cell, where the check valve option helps hold the grip if the upstream supply dips mid-cycle.

shield

Safety Clamp Hold-Up

Supply a workholding clamp circuit on a machining fixture, using the reverse valve so the clamped position is not lost during a momentary drop in shop air pressure.

factory

Stamping Press Feed Line

Feed counterbalance and part-ejector cylinders on a mechanical stamping press with filtered, regulated, lubricated air, the 5 um element protecting the press's pilot valves.

Is the AirTAC GC400-10 FRL Unit (GC40010C1WK) the Right Station?

This code differs from the plain GC40010C1W only by the K option: a check valve that blocks reverse flow, useful where a brief supply interruption must not dump a clamped or gripped circuit. The 5 um element suits finer-protection duty; 40 um versions are available. The round gauge reads in MPa, and psi or bar scales plus square-gauge variants exist in the series.

PT is the standard thread for this code, with G (BSPP) and NPT offered as catalogue options. The filter bowl is polycarbonate at size 400 with differential-pressure drain. Since flow appears only as curves in the catalogue, share your duty cycle and we will confirm the size choice against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010C1WK) FAQ

We do not state a rated flow figure because AirTAC publishes G-series flow as curves, not a single number. Send us your application and we will confirm capacity from the datasheet on request before you commit to a size.

The K option fits a reverse (check) valve in the set, so air will not flow back toward the regulator if upstream pressure falls. It is specified where a gripper, clamp or other circuit must hold its pressure through brief supply dips; the same set without K is available as GC40010C1W.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010C1WK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010C1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.