The AirTAC AirTAC GC400-10 FRL Unit (GC40010C1WK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series combines a separate air filter, pressure regulator and oil-mist lubricator into one three-piece F.R.L. set. The GC40010C1WK serves 3/8 in PT ports in size 400, uses the fine 5 um filter element (W) with the default differential-pressure drain, carries the external round gauge on an MPa scale, and is fitted with a reverse (check) valve (K) so downstream pressure is held if the upstream supply drops.
This is a genuine AirTAC part. The series spans sizes 200, 300, 400 and 600 with PT, G (BSPP) or NPT threads, 40 um or 5 um filtration, and MPa, psi or bar gauge scales. Maximum working pressure is 1.0 MPa (145 psi) with a -5 to 70 C, non-freezing temperature range. Flow is published as curves, not a single rating, so ask us to confirm sizing and datasheet figures on request.
| Model | AirTAC GC400-10 FRL Unit (GC40010C1WK) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
Condition the air feeding a six-axis robot's pneumatic gripper on a pick-and-place cell, where the check valve option helps hold the grip if the upstream supply dips mid-cycle.
Supply a workholding clamp circuit on a machining fixture, using the reverse valve so the clamped position is not lost during a momentary drop in shop air pressure.
Feed counterbalance and part-ejector cylinders on a mechanical stamping press with filtered, regulated, lubricated air, the 5 um element protecting the press's pilot valves.
This code differs from the plain GC40010C1W only by the K option: a check valve that blocks reverse flow, useful where a brief supply interruption must not dump a clamped or gripped circuit. The 5 um element suits finer-protection duty; 40 um versions are available. The round gauge reads in MPa, and psi or bar scales plus square-gauge variants exist in the series.
PT is the standard thread for this code, with G (BSPP) and NPT offered as catalogue options. The filter bowl is polycarbonate at size 400 with differential-pressure drain. Since flow appears only as curves in the catalogue, share your duty cycle and we will confirm the size choice against the datasheet before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
We do not state a rated flow figure because AirTAC publishes G-series flow as curves, not a single number. Send us your application and we will confirm capacity from the datasheet on request before you commit to a size.
The K option fits a reverse (check) valve in the set, so air will not flow back toward the regulator if upstream pressure falls. It is specified where a gripper, clamp or other circuit must hold its pressure through brief supply dips; the same set without K is available as GC40010C1W.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.