The AirTAC AirTAC GC400-10 FRL Unit (GC40010F1WK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC40010F1WK is an AirTAC GC-series three-unit F.R.L. combination for a 3/8in PT port, combining the fine 5um W filter element, a regulator and an oil-mist lubricator in one set. The regulator holds your set downstream pressure across 0.15-0.9 MPa (20-130 psi) with this differential-pressure drain configuration, the embedded square gauge reads in MPa, and the K in the code means a reverse (check) valve is fitted in the circuit.
This is a genuine AirTAC part in size 400 of the GC range (200/300/400/600). Maximum inlet pressure is 1.0 MPa (145 psi), the working temperature range is -5 to 70 C non-freezing, and the filter and lubricator bowls are polycarbonate at this size. AirTAC publishes flow as curves rather than a single rated figure, so ask us for the datasheet and we will confirm sizing for your circuit.
| Model | AirTAC GC400-10 FRL Unit (GC40010F1WK) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
Supplies the actuated fill and diverter valves on a bottling line, with the 5um element protecting the valve internals and a check valve fitted in the circuit.
Conditions the 3/8in service drops in a maintenance workshop where air tools, cylinders and blow guns share one filtered, regulated, lubricated supply.
Feeds grippers, clamps and pushers in a case-erecting and palletising cell that runs on clean, oiled, pressure-regulated air.
This code brings together three choices: the 5um W filter grade for particulate-sensitive circuits, the K option with the reverse (check) valve fitted, and the embedded square MPa gauge. Size 400 with a 3/8in PT port sits above the 300 series; step to 600 for larger demand. The drain is the differential-pressure default - select A for automatic or M for manual if your duty suits it better - and gauge scales 2 (psi) or 3 (bar) are orderable variants. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options. Because AirTAC publishes flow only as curves, ask us to confirm this model against your air demand before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
AirTAC states flow for this series as performance curves, not as a single rated number, so we will not quote a figure we cannot stand behind. Share your supply pressure and demand and we will confirm the sizing from the datasheet on request.
K specifies that a reverse (check) valve is fitted with the set. The same unit without the K is the GC40010F1W. Everything else decodes identically: size 400, 3/8in PT port, 5um element, differential-pressure drain, square MPa gauge and standard regulator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.