The AirTAC AirTAC GC400-10 FRL Unit (GC40010LC1W) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set, so a single supply line is filtered, regulated and oiled in the correct order. This GC40010LC1W is the 400 size with 3/8in PT ports, the fine 5 um filter element (W), a differential-pressure drain, a low-pressure type regulator and an external round pressure gauge reading in MPa. Like every GC set it runs on compressed air only, accepts up to 1.0 MPa (145 psi) inlet, works from -5 to 70 C (non-freezing), and uses polycarbonate bowls at this size.
It is a genuine AirTAC part from the G-series air-treatment range, which spans sizes 200, 300, 400 and 600 with ports from 1/8in to 1in, plus options such as automatic or manual drains, a 40 um standard element, G (BSPP) or NPT threads and psi or bar gauge scales. Flow for the series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet values for this exact model against your application.
| Model | AirTAC GC400-10 FRL Unit (GC40010LC1W) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
Supplies filtered, regulated and lubricated air to the pneumatic valve actuators and sample-handling cylinders on a chemical pilot-plant skid, with the 5 um element protecting small control valves and the round MPa gauge giving a clear setpoint readout.
Runs the clamp and lift cylinders on a bottling-hall filler carousel; the low-pressure type regulator suits a moderate line setting while the lubricator feeds the cylinder seals through every changeover cycle.
Feeds the divert gates and reject pushers on a pharmaceutical cartoning conveyor, where the 5 um grade keeps fine particles out of the small gate cylinders and the gauge lets the line engineer verify supply at a glance.
Step up to the 400 size when your line port is 3/8in and machine demand exceeds what a 300 set comfortably serves; larger sizes move more air, but the exact figures are curve-based, so let us check the sizing for you before ordering. The differential-pressure drain suits a steadily used line, while automatic and manual drains are alternatives within the series. The 5 um (W) element here gives finer protection than the standard 40 um grade. This version carries a round external gauge on the MPa scale; psi and bar scales are available, and G (BSPP) or NPT threads can be ordered in place of the PT standard.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
AirTAC publishes flow for the G series as performance curves, not as a single rated number, so we do not quote a figure here. Send us your required flow and inlet pressure and we will confirm the GC40010 datasheet curve against your application before you order.
The W in this code selects the 5 um element, which filters finer than the standard 40 um grade. It is the better choice where small control valves, gate cylinders or fittings sit downstream. If your circuit only needs general protection, the standard grade version of the same set is also available.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.