The AirTAC AirTAC GC400-10 FRL Unit (GC40010LF1) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series combines a separate air filter, pressure regulator and lubricator as a three-unit F.R.L. set, so one supply line is filtered, regulated and oiled in the right order. This GC40010LF1 is the 400 size with 3/8in PT ports, the standard 40 um filter element, a differential-pressure drain, a low-pressure type regulator and a square pressure gauge reading in MPa. Like every GC set it runs on compressed air only, accepts up to 1.0 MPa (145 psi) inlet, works from -5 to 70 C (non-freezing), and uses polycarbonate bowls at this size.
It is a genuine AirTAC part from the G-series air-treatment range, which spans sizes 200, 300, 400 and 600 with ports from 1/8in to 1in, plus options such as automatic or manual drains, a finer 5 um element, G (BSPP) or NPT threads and psi or bar gauge scales. Flow for the series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet values for this exact model against your application.
| Model | AirTAC GC400-10 FRL Unit (GC40010LF1) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
Conditions the shop air feeding a CNC machining centre's tool-change cylinder and air-blast nozzles; the square MPa gauge sits where the setter can see it and the lubricator keeps the change cylinders running smoothly.
Provides regulated, lubricated air to quarter-turn butterfly valve actuators at a water treatment plant, with the 40 um element stopping pipe scale from reaching the actuator seals.
Serves the pneumatic impact-wrench drop lines along a commercial-vehicle assembly line, where lubrication at the point of use keeps the wrenches working through a full shift.
Choose the 400 size when your line port is 3/8in and machine demand sits above what a 300 set comfortably serves; larger sizes carry more flow, but the figures are curve-based, so we can verify the sizing against your demand before you order. The differential-pressure drain suits a steadily used line, with automatic or manual drains as alternatives in the series. The 40 um element here is the standard grade, with the 5 um (W) option available where finer protection is needed. This version carries a square gauge on the MPa scale; psi and bar scales are offered, and G (BSPP) or NPT threads can be ordered in place of the PT standard.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
AirTAC publishes flow for the G series as performance curves, not as a single rated figure, so we do not state a number here. Tell us your required flow and working pressure and we will confirm the GC40010 datasheet curve against your application.
It is the gauge suffix: F is the square pressure gauge and 1 is the MPa scale. Psi (2) and bar (3) scales are available, and a version supplied without a gauge (N) exists for panels that carry their own instrumentation.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.