verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010LF1)

The AirTAC AirTAC GC400-10 FRL Unit (GC40010LF1) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$124.00 $130.76Save 5% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-10 FRL Unit (GC40010LF1)

The AirTAC GC series combines a separate air filter, pressure regulator and lubricator as a three-unit F.R.L. set, so one supply line is filtered, regulated and oiled in the right order. This GC40010LF1 is the 400 size with 3/8in PT ports, the standard 40 um filter element, a differential-pressure drain, a low-pressure type regulator and a square pressure gauge reading in MPa. Like every GC set it runs on compressed air only, accepts up to 1.0 MPa (145 psi) inlet, works from -5 to 70 C (non-freezing), and uses polycarbonate bowls at this size.

It is a genuine AirTAC part from the G-series air-treatment range, which spans sizes 200, 300, 400 and 600 with ports from 1/8in to 1in, plus options such as automatic or manual drains, a finer 5 um element, G (BSPP) or NPT threads and psi or bar gauge scales. Flow for the series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet values for this exact model against your application.

AirTAC GC400-10 FRL Unit (GC40010LF1) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010LF1)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010LF1)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010LF1) Is Used

precision_manufacturing

CNC machining centre air supply

Conditions the shop air feeding a CNC machining centre's tool-change cylinder and air-blast nozzles; the square MPa gauge sits where the setter can see it and the lubricator keeps the change cylinders running smoothly.

valve

Water-plant butterfly valve actuators

Provides regulated, lubricated air to quarter-turn butterfly valve actuators at a water treatment plant, with the 40 um element stopping pipe scale from reaching the actuator seals.

local_shipping

Truck assembly impact-wrench stations

Serves the pneumatic impact-wrench drop lines along a commercial-vehicle assembly line, where lubrication at the point of use keeps the wrenches working through a full shift.

Is the AirTAC GC400-10 FRL Unit (GC40010LF1) the Right Station?

Choose the 400 size when your line port is 3/8in and machine demand sits above what a 300 set comfortably serves; larger sizes carry more flow, but the figures are curve-based, so we can verify the sizing against your demand before you order. The differential-pressure drain suits a steadily used line, with automatic or manual drains as alternatives in the series. The 40 um element here is the standard grade, with the 5 um (W) option available where finer protection is needed. This version carries a square gauge on the MPa scale; psi and bar scales are offered, and G (BSPP) or NPT threads can be ordered in place of the PT standard.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010LF1) FAQ

AirTAC publishes flow for the G series as performance curves, not as a single rated figure, so we do not state a number here. Tell us your required flow and working pressure and we will confirm the GC40010 datasheet curve against your application.

It is the gauge suffix: F is the square pressure gauge and 1 is the MPa scale. Psi (2) and bar (3) scales are available, and a version supplied without a gauge (N) exists for panels that carry their own instrumentation.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010LF1)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010LF1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.