verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010MC1WK)

The AirTAC AirTAC GC400-10 FRL Unit (GC40010MC1WK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$135.35 $142.39Save 4% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-10 FRL Unit (GC40010MC1WK)

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator piped together to deliver clean, regulated, lubricated compressed air from one supply point. This GC40010MC1WK is built on the 400 size with a 3/8 in PT port, carries the fine 5 um filter element (the W grade) with a manual drain on the filter bowl, and includes a round external pressure gauge reading in MPa. A reverse (check) valve is fitted so downstream pressure is held if the supply side drops. Max working pressure is 1.0 MPa (145 psi); the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) with this manual-drain set, and the operating temperature range is -5 to 70 C, non-freezing. The filter and lubricator bowls in the 400 size are PC (polycarbonate).

This is a genuine AirTAC part. The G series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, and with catalogue choices of thread (PT standard, G and NPT to order), drain type, filter grade, gauge style and scale. Flow is published as characteristic curves rather than a single rated figure, so send us your application and we will confirm sizing and full datasheet details on request.

AirTAC GC400-10 FRL Unit (GC40010MC1WK) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010MC1WK)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010MC1WK)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010MC1WK) Is Used

precision_manufacturing

CNC machining centre clamping

Supplies the clean, regulated, lubricated air that pneumatic clamps and tool-changer cylinders on a machining centre depend on; the 5 um element protects fine spool valves from water and particulate.

air

Paint spray booth atomizing air

Prepares atomizing air for spray guns on a finishing line, where the 5 um element helps keep water carryover out of the finish and the lubricator mists the gun's air motor.

factory

Bottling line actuation

Keeps steady actuation pressure for filler, capper and labeling cylinders, while the fitted check valve holds downstream pressure if the plant supply dips during a compressor changeover.

Is the AirTAC GC400-10 FRL Unit (GC40010MC1WK) the Right Station?

The 400 size with a 3/8 in PT port is the mid-large step in the G range; if your air demand approaches what a 300-size unit can pass, stepping up to 400 reduces pressure loss. Drain type is a real choice here: this unit uses a manual drain, which suits supervised installations where an operator bleeds the bowl on a routine; choose the automatic drain code if the point is unsupervised. The 5 um element (W) is the fine grade for sensitive downstream equipment; the standard grade is 40 um. The round MPa gauge is external and easy to read at the set point, and PT is the standard thread with G and NPT available as order options.

Because rated flow is published as curves rather than a single figure, we cannot honestly quote one number for this unit. Ask us to confirm sizing against the datasheet curves for your line pressure and demand before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010MC1WK) FAQ

AirTAC publishes flow for the GC400 series as characteristic curves rather than a single rated figure, so we do not quote one number here. Send us your line pressure and air demand and we will confirm the sizing against the datasheet on request.

The 40 um grade is the standard element and handles general water and particulate removal. The 5 um (W) grade on this model is the finer option for sensitive downstream equipment such as precision valves, actuators and spray guns. Both grades are catalogue options across the GC series.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010MC1WK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010MC1WK and will confirm price, stock and lead time — usually within 7-8 hours.