verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015ALC1)

The AirTAC AirTAC GC400-15 FRL Unit (GC40015ALC1) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$134.44 $141.46Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-15 FRL Unit (GC40015ALC1)

GC40015ALC1 is an AirTAC GC-series three-unit F.R.L. combination: separate filter, regulator and lubricator assembled as one set. The L in the code specifies the low-pressure regulator type, whose adjustment extends up to 0.4 MPa, and the C1 suffix fits an external round pressure gauge scaled in MPa. This 400-size unit carries a PT1/2 port, automatic drain on the filter bowl and the standard 40 um filter element.

This is a genuine AirTAC part for compressed air, rated to 1.0 MPa (145 psi) maximum working pressure and -5 to 70 C (non-freezing). The 400 size uses polycarbonate bowls. With automatic drain the standard-type regulator spans 0.15 to 0.9 MPa, while this low-pressure type adjusts up to 0.4 MPa. Flow is published as curves rather than a single rated figure, so we confirm sizing and datasheet figures on request.

AirTAC GC400-15 FRL Unit (GC40015ALC1) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015ALC1)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015ALC1)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015ALC1) Is Used

science

Laboratory test rig actuation

Supplies gently regulated, filtered and lubricated air to clamps and actuators on a materials test rig, where the low-pressure regulator holds setpoints in the sub-0.4 MPa band.

view_module

Ceramic tile handling line

Conditions air for suction pads and transfer cylinders moving fragile tile sheets, with low-pressure regulation reducing the risk of over-clamping delicate ware.

settings_input_component

Food packaging clamshell closer

Feeds the pneumatic press cylinders on a clamshell packaging machine, where the 40 um element and automatic drain suit a washdown-adjacent, lightly attended line.

Is the AirTAC GC400-15 FRL Unit (GC40015ALC1) the Right Station?

Specify the L (low-pressure) type when your process runs below the standard adjustment band: this unit's regulator adjusts up to 0.4 MPa, whereas the standard GC400 regulator with automatic drain spans 0.15 to 0.9 MPa. Gauge is the round external type scaled in MPa here; square embedded gauges and MPa, psi or bar scales are the other decodable options. Filtration stays at the standard 40 um grade (5 um is the W alternative), drain is automatic, and thread is PT standard with G (BSPP) and NPT as orderable options.

Flow appears only as published curves, so ask us to confirm this size against your application demand before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015ALC1) FAQ

No single rated flow figure exists for this unit; AirTAC publishes GC-series flow data as performance curves. Send us your air demand and operating pressure and we will confirm the size and provide the datasheet on request before you order.

The L in the code selects the low-pressure regulator type, whose adjustment extends up to 0.4 MPa, suited to processes running below the standard band. On a standard GC400 with automatic drain the regulator adjusts from 0.15 to 0.9 MPa; here the round MPa gauge tracks the lower setpoints.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015ALC1)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015ALC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.