verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015C1W)

The AirTAC AirTAC GC400-15 FRL Unit (GC40015C1W) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$124.00 $130.76Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-15 FRL Unit (GC40015C1W)

The GC40015C1W is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as one set. It is size 400 with a 1/2 in. PT (standard) port, fitted with the 5 um (W) fine filter element for added protection of sensitive downstream components, a differential-pressure drain, and an external round gauge reading in MPa. The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with this drain type, and maximum inlet pressure is 1.0 MPa (145 psi).

This is a genuine AirTAC part from the G-series range, which covers sizes 200, 300, 400 and 600 with PT, G (BSPP) and NPT thread options. On this size 400 unit the filter bowl is polycarbonate, and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures for your application on request.

AirTAC GC400-15 FRL Unit (GC40015C1W) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015C1W)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015C1W)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015C1W) Is Used

science

Laboratory instrument air supply

Conditioning shop air feeding lab pneumatic devices and sample-handling actuators, where the 5 um element gives finer particle removal than the standard grade and the MPa gauge supports repeatable pressure settings.

view_module

Electronics assembly pick-and-place

Supplying filtered, regulated, lubricated air to the vacuum ejectors and slides of an electronics placement cell, with fine filtration helping protect the small pilot valves that control the heads.

tune

Paint booth air prep panel

Serving the air-preparation point ahead of a spray-booth control panel, giving the booth technician a visible MPa setting and finer-than-standard filtration for the coating line's control valves.

Is the AirTAC GC400-15 FRL Unit (GC40015C1W) the Right Station?

Choose this W version instead of the standard GC40015C1 when the 40 um default grade is not fine enough for the valves, cylinders or instruments you are feeding; 5 um is the finer option in the range. Size 400 with the 1/2 in. PT port suits demands between the 3/8 in. size 300 and the 3/4 in. size 600 steps, and drain choice remains yours: differential-pressure (this code), automatic (A) or manual (M).

The C1 round gauge reads in MPa, with psi and bar scale gauges available in the series, and thread is PT as standard with G and NPT as catalogue options. AirTAC publishes flow only as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015C1W) FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not state a number here. Give us your working pressure and required air consumption and we will confirm the correct size and element from the datasheet on request before ordering.

Choose 5 um (the W code) when the downstream equipment includes finely toleranced valves, instruments or applicators that need cleaner air than general machine supply; keep 40 um for normal cylinder and tool duty. This version keeps the differential-pressure drain and the MPa round gauge, so only the filtration grade changes versus the standard set.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015C1W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015C1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.