verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015C1WK)

The AirTAC AirTAC GC400-15 FRL Unit (GC40015C1WK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$135.35 $142.39Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-15 FRL Unit (GC40015C1WK)

The GC40015C1WK is a three-unit F.R.L. combination from AirTAC's G series: a separate air filter, pressure regulator and lubricator working together to deliver clean, regulated, oil-mist-lubricated compressed air to downstream equipment. This configuration uses 1/2 in. PT ports in the size 400 body, a differential-pressure drain on the filter bowl, the optional 5 um (W) filter element instead of the standard 40 um, a round external pressure gauge with an MPa scale, and a reverse/check valve fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the regulator adjusts from 0.15-0.9 MPa (20-130 psi) with this drain type; operating temperature is -5 to 70 C (non-freezing). The filter and lubricator bowls are PC (polycarbonate) at size 400.

This is a genuine AirTAC part. The G series is available in sizes 200, 300, 400 and 600, with automatic, manual or differential-pressure drains, 40 um or 5 um filtration, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads as catalogue options. Flow figures for the series are published as curves rather than a single rating, so ask us and we will confirm the datasheet and sizing for your application on request.

AirTAC GC400-15 FRL Unit (GC40015C1WK) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015C1WK)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015C1WK)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015C1WK) Is Used

precision_manufacturing

CNC machining centre air prep

Feeds the tool-clamp and chip-eject cylinders on a CNC machining centre, where the 5 um element protects precision valves from particulate carryover while the lubricator mists the clamp actuators.

conveyor_belt

Palletising conveyor diverters

Sits upstream of the diverter and stopper cylinders on a palletising conveyor line, holding a steady regulated pressure while metering oil mist to the actuators.

bolt

Bolt-tightening stations

Supplies pneumatic impact wrenches at an engine assembly station; the MPa gauge lets technicians set torque-consistent line pressure and the check valve holds the setting if supply dips.

Is the AirTAC GC400-15 FRL Unit (GC40015C1WK) the Right Station?

Choose size 400 with PT1/2 ports when your line flow and existing pipework call for a 1/2 in. connection; the 200/300/400/600 sizes step port size and flow capacity up or down. The 5 um W element suits downstream valves and cylinders that need finer filtration than the standard 40 um. The differential-pressure drain flushes the bowl automatically as the pressure differential builds - no daily manual draining. The MPa-scale round gauge reads the regulated outlet directly, and the fitted check valve prevents backflow. PT thread is the standard on this model; G (BSPP) and NPT are options to order. Because rated flow is published as curves, not a single number, send us your flow demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015C1WK) FAQ

AirTAC publishes G-series capacity as flow curves, not a single rated figure, so we do not quote one number here. Tell us your working pressure and air demand and we will confirm the flow from the datasheet on request before you order.

The W code selects the optional 5 um filter grade instead of the standard 40 um, and C1 selects the round external gauge with an MPa scale (psi and bar scales are also available). A differential-pressure drain, PT threads and the fitted reverse/check valve complete this configuration; each can be re-specified if your plant standard differs.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015C1WK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015C1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.