AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015C2)

The AirTAC AirTAC GC400-15 FRL Unit (GC40015C2) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$124.00 $130.76Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-15 FRL Unit (GC40015C2)

The GC40015C2 is a three-piece F.R.L. combination from AirTAC's G series: a separate air filter, pressure regulator and lubricator that together clean, regulate and oil-mist-lubricate the compressed air feeding your equipment. This configuration uses 1/2 in. PT ports in the size 400 body, a differential-pressure drain on the filter bowl, the standard 40 um filter element, and a round external pressure gauge with a psi scale for US-style readouts. Maximum inlet pressure is 1.0 MPa (145 psi) and the regulator adjusts from 0.15-0.9 MPa (20-130 psi) with this drain type; operating temperature is -5 to 70 C (non-freezing). The filter and lubricator bowls are PC (polycarbonate) at size 400.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600, with automatic, manual or differential-pressure drains, 40 um or 5 um filtration, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads as catalogue options. Flow for the series is published as curves rather than a single rating, so ask us and we will confirm the datasheet and sizing for your application on request.

AirTAC GC400-15 FRL Unit (GC40015C2) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015C2)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015C2)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015C2) Is Used

factory

Packaging line fill-and-seal

Prepares air for the fill heads and sealing jaws on a vertical form-fill-seal packaging machine, keeping water and 40 um particulate out of the seal cylinders while feeding them a metered oil mist.

science

Lab automation actuators

Conditions supply to the pneumatic actuators on laboratory sampling and dispensing equipment, where the psi-scale gauge matches US instrument readouts.

conveyor_belt

Bottling line rail adjusters

Regulates and lubricates air to the bottle-guide rail adjusters and lift cylinders on a beverage bottling conveyor, holding steady pressure through changeovers.

Is the AirTAC GC400-15 FRL Unit (GC40015C2) the Right Station?

Size 400 with PT1/2 ports suits lines built around 1/2 in. pipework and higher air demand; step to 200/300 for lighter duty or to 600 for the largest ports and flow capacity. The standard 40 um element is the usual choice for general plant air, with the 5 um W grade available when finer filtration is needed. The psi-scale round gauge reads the regulated outlet in familiar US units. The differential-pressure drain clears the bowl automatically as the pressure differential builds. PT thread is the standard on this model; G (BSPP) and NPT are options to order. Rated flow is published as curves, not a single figure, so share your flow demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015C2) FAQ

AirTAC publishes G-series flow as curves rather than a single rated number, so we do not state a figure here. Give us your working pressure and air consumption and we will confirm the sizing from the datasheet on request.

Yes. The C2 code means a round external gauge with a psi scale; MPa and bar scales are catalogue alternatives. The differential-pressure drain can be swapped for automatic (A) or manual (M), and G (BSPP) or NPT threads can be ordered in place of the standard PT.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015C2)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015C2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.