The AirTAC AirTAC GC400-15 FRL Unit (GC40015LN) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$118.35 $124.97Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-15 FRL Unit (GC40015LN)

The GC40015LN is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator working as one set. Size 400 with PT1/2 (PT thread) ports suits a 1/2 inch compressed-air main, and this version is the low-pressure type with no gauge fitted. The filter element is the standard 40 um grade, the filter bowl drains by differential pressure, and together the three units clean, regulate at a low setting and oil-mist lubricate the air going to your equipment. The filter-section bowl in size 400 is polycarbonate (PC).

This is a genuine AirTAC part. The G-series runs from size 200 to 600, with options that include automatic or manual drains, a 5 um filter element, embedded square or external round gauges, and G (BSPP) or NPT threads as catalogue choices. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow for G-series units is published as curves rather than a single rating, so we confirm figures from the datasheet on request.

AirTAC GC400-15 FRL Unit (GC40015LN) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015LN)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015LN)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015LN) Is Used

air

Air-knife drying line

Feeds filtered, low-pressure regulated air to air knives that blow water off bottles or cans on a bottling conveyor before labelling, with the lubricator protecting any downstream pneumatics on the same line.

factory

Textile air-jet loom supply

Conditions the compressed air feeding weft-insertion jets on an air-jet weaving loom, where the low-pressure regulator type matches the low working pressure the loom's air circuit runs at.

conveyor_belt

Packaging conveyor cylinders

Cleans, regulates and lubricates the air supply to carton-flap tuck and pusher cylinders on a packaging conveyor, keeping moisture and particles out of the valve manifold.

Is the AirTAC GC400-15 FRL Unit (GC40015LN) the Right Station?

Choose size 400 (PT1/2) when a 1/2 inch main feeds several cylinders or a larger actuator; the smaller GC200 and GC300 sets cover lighter duty. The L in this code marks the low-pressure type of the regulator section, intended for circuits where the working pressure sits well below normal shop-air settings - send us your set pressure and we will confirm the adjusting range on the datasheet before you order. Drain here is the differential-pressure default; automatic (A) and manual (M) versions exist in the series. Filter grade is the standard 40 um; specify W for 5 um. Thread is PT as standard, with G (BSPP) and NPT (T) as orderable options. A gauge can be added as an embedded square or external round unit if you want a visual setpoint.

Because G-series flow is published as curves and not as a single rated figure, we do not quote a flow number here. Ask us to confirm sizing of the GC40015LN against your application and the AirTAC datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015LN) FAQ

AirTAC publishes G-series flow as performance curves, not as a single rated figure, so we do not quote a flow number on the page. Tell us your air demand and line pressure and we will confirm the sizing from the datasheet on request before you order.

L marks the low-pressure type of the regulator section, used where the downstream working pressure is well below normal shop-air settings. If your circuit regulates around standard pressures, the version without L is the usual choice; we can confirm the right type and its adjusting range from the datasheet on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015LN)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015LN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.