verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015LNK)

The AirTAC AirTAC GC400-15 FRL Unit (GC40015LNK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$129.70 $136.60Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-15 FRL Unit (GC40015LNK)

The GC40015LNK is a three-piece AirTAC G-series F.R.L. combination - separate air filter, pressure regulator and lubricator - supplied in size 400 with PT1/2 ports and a PT thread. The K in the code means a reverse (check) valve is fitted in the regulator section, so downstream pressure is held if the upstream supply dips. This version is the low-pressure type with no gauge, a standard 40 um filter element, and a differential-pressure drain on the polycarbonate (PC) filter bowl.

This is a genuine AirTAC part. The G-series spans sizes 200 to 600 with options including automatic or manual drains, a 5 um element, embedded square or external round gauges, and G (BSPP) or NPT threads as catalogue choices. Maximum working pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm figures from the datasheet on request.

AirTAC GC400-15 FRL Unit (GC40015LNK) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015LNK)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015LNK)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015LNK) Is Used

bolt

Pneumatic clamping fixture

Supplies filtered, low-pressure regulated air to clamping cylinders on a machining cell, where the fitted check valve helps hold the clamp circuit while the upstream supply fluctuates.

settings_input_component

Pick-and-place module

Conditions the air feeding a pick-and-place handling module on an assembly line, keeping particles and water out of the valve island while the lubricator mists the actuators' air.

engineering

Test-rig actuation skid

Provides clean, regulated, lubricated air to the actuated cylinders on a low-pressure test rig, with the check valve holding the set circuit pressure during supply interruptions.

Is the AirTAC GC400-15 FRL Unit (GC40015LNK) the Right Station?

Pick this model over the plain GC40015LN when a supply-side pressure dip must not dump your regulated downstream pressure - the fitted check valve holds the circuit while the upstream side recovers, useful on clamping and holding circuits. Size 400 with PT1/2 ports suits a 1/2 inch main feeding multiple actuators. The L marks the low-pressure regulator type; give us your set pressure and we will confirm the adjusting range on the datasheet. Drain is the differential-pressure default (automatic A and manual M exist). Filter grade is 40 um standard, 5 um with W. Thread is PT as standard; G (BSPP) and NPT (T) are orderable options, and a square or round gauge can be added.

Flow for G-series units is published as curves, not a single rated figure, so send your flow demand and we will confirm sizing against the AirTAC datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015LNK) FAQ

We do not state a rated flow number because AirTAC publishes G-series flow as curves rather than a single rating. Share your application's flow and pressure and we will confirm the sizing from the datasheet on request before you order.

K means a reverse (check) valve is fitted in the regulator section. It blocks reverse flow, so the regulated downstream pressure is held if the upstream supply drops - the plain GC40015LN without K has no check valve. We can confirm details on the datasheet on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015LNK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015LNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.