verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC400C10F1WK

The AirTAC Airtac GC FRL Unit GC400C10F1WK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$151.24 $158.68Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC400C10F1WK

GC400C10F1WK is AirTAC's three-unit F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled in the 400 size with PT3/8 ports. This configuration carries the fine 5 um (W) filter element, the differential-pressure drain, an embedded square gauge with an MPa scale, and the K option, which fits a reverse (check) valve in the regulator. Maximum inlet pressure is 1.0 MPa (145 psi); with the differential-pressure drain the regulator adjusts from 0.15-0.9 MPa (20-130 psi); the medium is compressed air and the working temperature range is -5 to 70 C (non-freezing). The filter and lubricator bowls on this 400 size are PC (polycarbonate).

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and GC sets can be ordered with 40 um or 5 um filtration, differential-pressure, automatic or manual drains, MPa, psi or bar gauge scales, G (BSPP) or NPT threads in place of the PT standard, and an optional mounting bracket. Flow for this series is published as curves rather than a single rating, so contact us and we will confirm the datasheet figures on request.

Airtac GC FRL Unit GC400C10F1WK Technical Specifications

ModelAirtac GC FRL Unit GC400C10F1WK
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC400C10F1WK

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC400C10F1WK Is Used

air

Spray coating line

Atomizing-air preparation on a spray coating line: the 5 um element keeps the supply clean before the atomizers, the check valve backs up the regulated circuit, and the lubricator serves the air-driven reciprocating spray movers.

factory

Bottling hall actuators

Supply air for the filler and capper cylinders in a bottling hall, where the three-unit set cleans, regulates and lubricates the air feeding a dense cluster of cylinders and pilot valves.

settings_input_component

Pneumatic control panel

Panel-mounted air conditioning ahead of a bank of directional control valves on a machine control skid, with the 5 um grade protecting pilot stages and the MPa gauge giving a clear setpoint reference.

Is the Airtac GC FRL Unit GC400C10F1WK the Right Station?

Decodable choices here: the 400 size with PT3/8 ports (move to 600 or 300 if your porting or expected flow differs), the 5 um W element instead of the standard 40 um, the differential-pressure drain, and the K suffix that adds the reverse (check) valve. The embedded square gauge reads MPa, with psi and bar scales as alternatives. PT is the standard thread, with G (BSPP) and NPT available as catalogue options, and a mounting bracket is optional. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

Airtac GC FRL Unit GC400C10F1WK FAQ

Flow for the G series is published as curves, not as a single rated number, so we do not state one here. Share your pressure and demand details and we will confirm the datasheet flow figures on request.

K indicates that a reverse (check) valve is fitted in the regulator section of this GC set. Sets without the K suffix have no check valve; it is a decodable ordering option, not an extra part you add yourself.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC400C10F1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C10F1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.