The AirTAC Airtac GC FRL Unit GC400C15MC1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC400C15MC1W is a three-piece F.R.L. combination: separate air filter, pressure regulator and lubricator in line. This 400-size unit takes PT1/2 ports, drains its filter bowl manually, and filters to the finer 5 um grade (the W option) for cleaner downstream air. A round external gauge reads regulated pressure in MPa.
This is a genuine AirTAC part from the G series, offered in 200, 300, 400 and 600 sizes with drain-type, filter-grade, gauge and thread options (PT standard, G and NPT to order). Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | Airtac GC FRL Unit GC400C15MC1W |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Installed ahead of the control valves on a lab autoclave and steriliser installation, this set delivers 5 um-filtered, regulated, lubricated air so that gate and loading cylinders operate reliably in a hygiene-conscious environment.
Mounted at the inlet of a fixture-clamping circuit on an assembly press, it supplies clean air at a fixed regulated pressure so clamps hold workpieces consistently, with the 5 um element protecting fine-metering valves in the circuit.
Fitted in the power pack of a loading-dock leveller, the unit conditions the air driving the leveller and restraint cylinders, keeping moisture and particles out of the control valves on a busy shipping bay.
GC400C15MC1W pairs the 400 size with PT1/2 ports and the 5 um element, the right choice when downstream valves or actuators need cleaner air than the standard 40 um grade delivers. If demand is lighter, the 300 size on 3/8" covers smaller lines; heavier demand steps up to the 600 size. Manual drain means an operator clears the bowl on a routine walk-round; automatic or differential-pressure drain variants exist for unattended points.
The gauge here is the round external type on an MPa scale; embedded square gauges and psi or bar scales are alternatives. Thread is PT as standard, with G (BSPP) and NPT as orderable options. Flow appears only as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes G-series flow as characteristic curves rather than a single rated value, so we cannot honestly quote one number. Share your line pressure and consumption and we will confirm the sizing and datasheet flow data for this 400-size, PT1/2 unit on request.
W selects the 5 um filter element instead of the standard 40 um grade, giving finer particulate removal in the filter bowl. Everything else in the code stays the same: 400 size, PT1/2 ports, manual drain, standard regulator with a round MPa gauge, and no reverse valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.