The AirTAC Airtac GC FRL Unit GC400C15MNWK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, a pressure regulator and a lubricator working as one coordinated set, so the compressed air feeding your circuit is cleaned, regulated and oiled in sequence. This GC400C15MNWK is the size 400 unit with a PT1/2 (1/2 in) port, a manual drain on the filter bowl, 5 um filtration (the W code, one step finer than the 40 um standard element), the standard regulator type, no gauge fitted and a reverse (check) valve built in, which holds downstream pressure if the upstream supply is cut or drops. With manual drain, the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi); the set is rated for a 1.0 MPa (145 psi) maximum working pressure and -5 to 70 C, non-freezing. At size 400 the filter and lubricator bowls are polycarbonate.
This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600, with drain choices (differential-pressure, automatic or manual), the 5 um element option, gauge options, a reverse/check valve code and G (BSPP) or NPT thread variants to order. Flow is published as curves rather than a single rating, so ask us to confirm sizing and the datasheet figures for your application.
| Model | Airtac GC FRL Unit GC400C15MNWK |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Supplying the pneumatic clamps on a press tool, where the 5 um element protects the pilot valves and the check valve holds clamp pressure if the shop-air supply dips mid-stroke.
Regulating and lubricating air to the actuator circuits on an analytical-instrument skid, with 5 um filtration and the manual drain emptied during scheduled service rounds.
Feeding the diverter and stopper cylinders on a parcel-sorting conveyor, where the check valve holds downstream pressure through supply transients and the lubricator serves the cylinders.
Size 400 with a 1/2 in port sits in the upper-middle of the G range; step up to size 600 or down to size 300 depending on the flow your line needs - we can read the published flow curves against your demand before you order. The W code selects the 5 um filter element instead of the 40 um standard, for finer protection of pilot valves and precision actuators. The M code gives a manual drain, so condensate is emptied by hand during inspection rounds; automatic or differential-pressure drain codes are available. The K code adds a reverse (check) valve where downstream pressure must be held through a supply dip. The N code means no gauge is supplied, though gauge options exist in the series. PT is the standard thread, with G (BSPP) and NPT variants to order. Because flow is published as curves, not a single rating, ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
Flow for the G series is published as curves rather than a single rated figure, so we do not quote one number here. Tell us your operating pressure and demand and we will confirm the sizing and the datasheet figures for this model on request.
W selects the 5 um filter element instead of the 40 um standard, for finer particulate protection. K specifies a reverse (check) valve fitted in the unit, so downstream pressure is held and backflow is prevented if the upstream supply drops. Both codes can be ordered independently on the same series.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.