The AirTAC Airtac GC FRL Unit GC400C15N is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC400C15N is a genuine AirTAC three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, matched as a set for 1/2 inch PT ports. This configuration carries the standard 40 um filter element with the default differential-pressure drain on the filter bowl, and the N code means no pressure gauge is fitted. In use it cleans water and particulate out of the compressed air, holds a steady downstream pressure adjustable from 0.15-0.9 MPa (20-130 psi), and meters oil mist into the air line to lubricate downstream tooling.
This is a genuine AirTAC part in the G series size 400 range, which spans sizes 200, 300, 400 and 600 with a choice of ports, threads, drains, filter grades and gauge options. Maximum working pressure is 1.0 MPa (145 psi) and the service temperature range is -5 to 70 C (non-freezing); the bowls on this size are PC (polycarbonate). Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet flow and sizing figures on request.
| Model | Airtac GC FRL Unit GC400C15N |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Installed on the compressed air drop feeding a CNC machining centre, the set dries and filters the supply, holds a stable pressure to the machine's pneumatic circuits and lubricates the air going to tool-change and clamping cylinders.
Mounted at the inlet of a packaging machine's air preparation panel, it conditions the supply before distribution to sealing jaws, diverters and pusher cylinders, protecting valves from water and debris while keeping moving parts oiled.
Fitted at take-off points on a factory ring main, the combination gives each production cell its own filtered, regulated and lubricated air supply independent of what neighbouring cells draw from the same header.
Start with size and port: the 400 series with its 1/2 inch PT port suits mid-to-large air lines, and stepping up to 600 or down to 300 changes the port and the flow capacity, so match the step to the air demand of the circuit. Drain choice on the filter is differential-pressure here (the default); automatic (A) and manual (M) drains are orderable options. The standard element is 40 um, with a finer 5 um (W) element available if the application calls for it. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options. This N-coded unit comes without a gauge; gauge and scale variants can be ordered instead if a local pressure readout is wanted. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and line conditions and we will confirm the datasheet flow figures and check the sizing for you on request.
Yes. The N in GC400C15N means no pressure gauge is fitted as standard; gauge and scale variants of the same GC400 set can be ordered instead if you want a local readout of the regulated pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.