The AirTAC AirTAC GC600-20 FRL Unit (GC60020AF1W) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC60020AF1W is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator working together to clean, regulate and oil-mist lubricate compressed air. This configuration is size 600 with a 3/4 in PT port, fitted with an automatic drain on the filter bowl, a fine 5 um filter element, a square embedded gauge scaled in MPa, and the standard regulator (no low-pressure type or reverse valve). Maximum working pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with this automatic-drain setup, and the 600-size bowls are aluminium alloy.
This is a genuine AirTAC part from the G series, which spans sizes 200, 300, 400 and 600 with a full choice of ports, threads, drains, filter grades and gauges. Published flow data appears as curves rather than a single rating, so we confirm flow and datasheet figures on request before you order.
| Model | AirTAC GC600-20 FRL Unit (GC60020AF1W) |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT3/4" · 5 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-20 |
| Build order | Filter → regulator → lubricator |
Feeds cleaned, regulated and lubricated air to the clamping fixtures, tool-change cylinders and chip-ejection jets on a CNC machining centre supplied from a 3/4 in plant air drop.
Conditions supply to the pneumatic cylinders that drive case erecting, flap folding and product pushers on a carton packaging line, with the 5 um element protecting close-tolerance valve spools.
Serves the air-over-oil intensifiers and hold-down clamps on an automated assembly press, where the regulator holds a steady set pressure and the lubricator mists the actuator seals.
Size 600 with a 3/4 in port is the largest step in the G series, so start here when your line demand sits above what a 400-size unit carries; step down to 300 or 400 for smaller branches. The 5 um element in this code suits downstream equipment that tolerates less particulate than the 40 um standard element; choose 40 um where general plant air is enough. The automatic drain on this code evacuates condensate without operator attention, which suits unmanned or hard-to-reach installations. The square gauge here is scaled in MPa; psi (F2) and bar (F3) versions of the same size exist. PT thread is the standard on this code, and G (BSPP) or NPT versions can be ordered as catalogue options. Because flow is published as curves rather than one rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.
AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line demand and operating pressure and we will confirm the sizing against the datasheet curves on request before you order.
In the G series the letter W in the code denotes the optional 5 um filter element instead of the 40 um standard, and F1 denotes the embedded square gauge scaled in MPa. If you prefer psi or bar readout, the F2 and F3 versions of the same 600-20 unit are available, and the plain 40 um version omits the W.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.