verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-25 FRL Unit (GC60025AC1K)

The AirTAC AirTAC GC600-25 FRL Unit (GC60025AC1K) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$209.35 $218.23Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC600-25 drain, gauge and thread option on one page All GC600-25 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC600-25 FRL Unit (GC60025AC1K)

The GC60025AC1K is an AirTAC G-series three-unit F.R.L. combination: separate air filter, pressure regulator and lubricator units assembled as one set for compressed air. This configuration is size 600 with PT 1 inch ports, an automatic drain on the filter bowl, a 5 um filter element, a round external gauge scaled in MPa and a fitted reverse (check) valve. The regulator adjusts 0.15-0.9 MPa (20-130 psi) with this drain type, maximum inlet pressure is 1.0 MPa (145 psi), the aluminum alloy bowls suit the large 600 frame, and working temperature is -5 to 70 C.

This is a genuine AirTAC part. The G series runs from size 200 to 600 with ports from 1/8 to 1 inch, and this set can be ordered with the standard 40 um element, a manual or differential-pressure drain, a psi or bar gauge scale, or G (BSPP) and NPT threads in place of the PT standard. AirTAC publishes 600-size flow as curves rather than one rated figure; ask us to confirm the datasheet numbers for your application before ordering.

AirTAC GC600-25 FRL Unit (GC60025AC1K) Technical Specifications

ModelAirTAC GC600-25 FRL Unit (GC60025AC1K)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-25 FRL Unit (GC60025AC1K)

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-25 FRL Unit (GC60025AC1K) Is Used

precision_manufacturing

Robotic weld cells

Filtered, regulated and lubricated air for weld-gun clamping actuators on an automotive body line, with the fitted check valve blocking reverse flow in the circuit.

conveyor_belt

High-speed packaging conveyors

Supplies the cylinders that divert, stop and stack cartons on a bottling plant conveyor, with automatic drain keeping condensate out of the valves between shifts.

valve

Actuated valve skids

Prepares air for quarter-turn actuator supply on a water treatment valve manifold, with the MPa gauge matching the plant's metric instrumentation.

Is the AirTAC GC600-25 FRL Unit (GC60025AC1K) the Right Station?

Size 600 with a 1 inch port is the largest step in the G series; step down to 400, 300 or 200 (3/4 to 1/8 inch) when your circuit uses less air. Drain choices are differential-pressure (default), automatic (this model) and manual; automatic suits lines that run unattended. The 5 um W element is the finer option against the 40 um standard. Gauge here is a round external gauge reading in MPa; psi or bar scales and the embedded square gauge are alternatives, and the K option adds a reverse (check) valve. Threads: PT is the standard, with G (BSPP) and NPT as orderable options. AirTAC publishes flow as curves, not one rated number, so send us your flow demand and working pressure and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

AirTAC GC600-25 FRL Unit (GC60025AC1K) FAQ

AirTAC does not publish a single rated flow figure for the G series; capacity is given as flow curves across pressures and port sizes, so we do not quote a number as a rating. Tell us your required flow and working pressure and we will confirm the datasheet curve values for the 600 size on request before you order.

K marks that a reverse (check) valve is fitted to the set, which blocks reverse flow through the unit; the same combination without the valve is coded GC60025AC1W. The rest of the code decodes as size 600, PT 1 inch ports, automatic drain (A), 5 um filter element (W) and a round MPa gauge (C1).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC600-25 FRL Unit (GC60025AC1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC60025AC1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.