AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain

The AirTAC AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$71.13 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain

The AirTAC GC200-08 is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit, giving a compressed-air supply that is cleaned of water and particulate down to 5 um, regulated and lubricated in a single mounting. This configuration is built on the 200 size with a G1/4 (1/4 in) port, G (BSPP) thread, a manual-drain bowl in polycarbonate, a 5 um filter element, a low-pressure regulator, an embedded square gauge scaled in psi, a fitted reverse/check valve and an included mounting bracket. The reverse/check valve holds the downstream circuit against backflow, and the manual drain is emptied by hand on a maintenance routine you set.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with choices of thread (PT standard; G and NPT as order options), drain type, filter grade (40 um standard, 5 um optional), gauge style and scale, and reverse/check valve. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.

AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain Technical Specifications

ModelAirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain Is Used

factory

Bottling and packaging line air supply

Feeding the pneumatic grippers, clamp cylinders and label heads on a bottling or carton-packing line, where one point-of-use unit cleans the air to 5 um, holds a low regulated pressure and delivers oil mist to keep the actuators running smoothly through each shift.

conveyor_belt

Food-grade conveyor diverters and pushers

Supplying the air cylinders that divert, stop and push product along conveyor lines, where the 5 um element protects the small control valves from water and particulate, the lubricator carries oil mist downstream, and the psi gauge lets line staff verify supply at a glance.

precision_manufacturing

Machine-shop fixture and clamp circuits

Powering workholding clamps and swing cylinders on CNC fixtures, where the reverse/check valve helps hold the clamped circuit against supply fluctuations, the low-pressure regulator suits light clamping forces, and the 5 um grade keeps the fine metering valves clean.

Is the AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain the Right Station?

Size up by port and required flow: this unit is the 200 size at G1/4 (1/4 in); larger sizes (300/400/600) carry larger ports and more flow, so step up if your line demand exceeds what a 1/4 in supply can pass. The 5 um element (code W) is the finer option over the 40 um standard - choose it where downstream valves and cylinders need cleaner air, and note the manual drain suits installations you already service on a schedule; automatic or differential-pressure drains are available elsewhere in the series if you prefer hands-off drainage. The low-pressure regulator is intended for circuits running below the standard regulator range; the exact range is not published, so confirm it with us before ordering. The fitted square gauge reads in psi (MPa and bar scales are alternatives), the reverse/check valve is already fitted, and the bracket is included. Thread here is G (BSPP); PT is the catalogue standard and NPT is also orderable. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Send us your application details and we will confirm the flow figures from the datasheet and check the sizing against your demand before you order.

The L in the code GC20008MLF2WGK specifies the low-pressure regulator type, intended for circuits running below the standard regulator range; the exact range is not published, so confirm it with us for your setpoint. The M specifies a manual drain, meaning the polycarbonate bowl is emptied by hand on a maintenance routine - if you would rather not drain by hand, the series also offers automatic and differential-pressure drain options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC200-08 F.R.L. Unit, G1/4, 5 um, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20008MLF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.