The AirTAC AirTAC GC20006MLC2W F.R.L. Unit, PT1/8, 5 um Filter is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC20006MLC2W is a three-piece AirTAC F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply unit. This size 200 configuration is ported PT1/8, carries a 5 um filter element (code W) with a manual drain on the filter bowl, and uses the low-pressure regulator type fitted with an external round gauge scaled in psi. The bowls are polycarbonate at this size, the mounting bracket is included, and the unit handles compressed air at up to 1.0 MPa (145 psi) inlet in a -5 to 70 C (non-freezing) environment.
This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600 with port sizes stepping from 1/8 in up to 1 in, and with choices of drain type, filter grade, gauge style and scale, thread (PT standard, G and NPT to order) and a reverse/check valve option. Published flow data appears as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | AirTAC GC20006MLC2W F.R.L. Unit, PT1/8, 5 um Filter |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeding carton sealers, case erectors and bagging machines on a packaging line, where filtered, regulated and lubricated air keeps cylinders and actuators running cleanly shift after shift.
Supplying the clamps, tool-changer cylinders and air-powered fixtures on a CNC machining centre, with the 5 um element protecting downstream valves from fine contamination.
Conditioning the air at a truck and trailer maintenance shop, where the lubricator oil-mists impact wrenches and air tools and the low-pressure regulator type matches the shop's line circuit.
Size and port are the first decision: step up through 200/300/400/600 and the matching port (here PT1/8) as your air demand grows. The filter element is 40 um as standard or 5 um with the W code - this unit carries the 5 um element for finer particulate and water removal ahead of the regulator and lubricator. The drain is manual on this configuration, so the bowl is emptied by hand; automatic and differential-pressure drains are available if you prefer unattended operation. The regulator here is the low-pressure type with a round gauge scaled in psi; the embedded square gauge and MPa or bar scales are the other catalogue options. Thread is PT as standard, with G (BSPP) and NPT as order options, and the mounting bracket is included. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Send us your air demand and line conditions and we will confirm the datasheet flow figures and check the sizing for your application on request.
This configuration uses a manual drain: the filter bowl is emptied by hand as part of routine checks. If you would rather not rely on an operator, the same GC200 size is available with an automatic drain or the standard differential-pressure drain - tell us which you prefer when ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.