AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter

The AirTAC AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$135.86 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter

The AirTAC GC40015ALC2W is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-treatment set. This configuration is built for a 1/2 in PT port and carries the fine 5 um filter element (code W) with an automatic drain, so condensate is expelled from the filter bowl without manual attention. The regulator is the low-pressure type, and this unit is fitted with an external round gauge scaled in psi. Maximum working (inlet) pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The filter and lubricator bowls are PC (polycarbonate), and a mounting bracket is included.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 40 um standard or 5 um (W) filter element, standard or low-pressure regulation, gauge style and scale options, PT, G or NPT threads, and reverse/check valve variants. Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet figures for your application before ordering.

AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter Technical Specifications

ModelAirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter Is Used

precision_manufacturing

Pneumatic press and clamping stations

Feeds filtered, regulated and lubricated air to a 1/2 in pneumatic press or clamp circuit, where the 5 um element protects valves and cylinders and the low-pressure regulator suits circuits running at reduced settings.

conveyor_belt

Packaging and conveyor actuation lines

Supplies treated air to packaging machinery and conveyor diverters on a 1/2 in main drop, with the automatic drain keeping condensate out of the line during continuous shifts and the lubricator misting downstream actuators.

factory

Plant air drops for assembly cells

Installed as a point-of-use F.R.L. on a factory assembly-cell air drop, conditioning the supply before it reaches air tools and cylinders, with the psi gauge giving operators a local pressure readout.

Is the AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter the Right Station?

Start with the size step: 200, 300, 400 and 600 correspond to increasing port size and flow capacity, so match the size to the air demand of the downstream circuit - this unit sits at size 400 with a 1/2 in PT port. Choose the drain type where a bowl is fitted: differential-pressure (default), automatic (as here), or manual. Choose the filter grade: 40 um standard or 5 um (W) for finer particulate removal, as selected here. For the regulator, pick standard or low-pressure type, and select the gauge style (embedded square standard, external round optional) and scale (MPa, psi or bar - this unit has a round psi gauge). Select the thread: PT is the standard, with G (BSPP) and NPT available as order options. A bracket is included with this unit.

One honest note on sizing: flow is published as curves, not a single rated figure, so please ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and we will confirm the flow and datasheet figures for this 1/2 in, size 400 unit on request.

The A in the code sets the automatic drain, which expels collected condensate from the filter bowl without manual intervention - useful on lines that run unattended. The W sets the 5 um filter element instead of the 40 um standard, giving finer particulate removal ahead of the regulator and lubricator.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015ALC2W and will confirm price, stock and lead time — usually within 7-8 hours.