The AirTAC AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC40015ALC2W is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-treatment set. This configuration is built for a 1/2 in PT port and carries the fine 5 um filter element (code W) with an automatic drain, so condensate is expelled from the filter bowl without manual attention. The regulator is the low-pressure type, and this unit is fitted with an external round gauge scaled in psi. Maximum working (inlet) pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The filter and lubricator bowls are PC (polycarbonate), and a mounting bracket is included.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 40 um standard or 5 um (W) filter element, standard or low-pressure regulation, gauge style and scale options, PT, G or NPT threads, and reverse/check valve variants. Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet figures for your application before ordering.
| Model | AirTAC GC40015ALC2W F.R.L. Unit, PT1/2, 5 um Filter |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to a 1/2 in pneumatic press or clamp circuit, where the 5 um element protects valves and cylinders and the low-pressure regulator suits circuits running at reduced settings.
Supplies treated air to packaging machinery and conveyor diverters on a 1/2 in main drop, with the automatic drain keeping condensate out of the line during continuous shifts and the lubricator misting downstream actuators.
Installed as a point-of-use F.R.L. on a factory assembly-cell air drop, conditioning the supply before it reaches air tools and cylinders, with the psi gauge giving operators a local pressure readout.
Start with the size step: 200, 300, 400 and 600 correspond to increasing port size and flow capacity, so match the size to the air demand of the downstream circuit - this unit sits at size 400 with a 1/2 in PT port. Choose the drain type where a bowl is fitted: differential-pressure (default), automatic (as here), or manual. Choose the filter grade: 40 um standard or 5 um (W) for finer particulate removal, as selected here. For the regulator, pick standard or low-pressure type, and select the gauge style (embedded square standard, external round optional) and scale (MPa, psi or bar - this unit has a round psi gauge). Select the thread: PT is the standard, with G (BSPP) and NPT available as order options. A bracket is included with this unit.
One honest note on sizing: flow is published as curves, not a single rated figure, so please ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and we will confirm the flow and datasheet figures for this 1/2 in, size 400 unit on request.
The A in the code sets the automatic drain, which expels collected condensate from the filter bowl without manual intervention - useful on lines that run unattended. The W sets the 5 um filter element instead of the 40 um standard, giving finer particulate removal ahead of the regulator and lubricator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.