verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain

The AirTAC AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$136.48 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain

The AirTAC GC400 is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one air-preparation set. This configuration is the size 400 unit with a G1/2 (BSPP) port. It removes water and particulate down to 5 um (the finer of the two published grades), regulates downstream pressure with the low-pressure type regulator, and adds oil-mist lubrication for downstream air tools and cylinders. The bowls are drained manually, a round psi gauge is fitted, a reverse/check valve is included, and a mounting bracket is supplied. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The polycarbonate bowls suit this size; only the 600 size uses aluminium alloy bowls.

This is a genuine AirTAC part. The GC family is published in sizes 200, 300, 400 and 600, with port sizes from 1/8 in up to 1 in, thread options PT (standard), G and NPT, drain choices, 40 um or 5 um filtration, gauge and scale choices, and a reverse/check valve option. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.

AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain Technical Specifications

ModelAirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain Is Used

precision_manufacturing

Machine shop pneumatic clamping and workholding

On CNC fixtures and clamping circuits running at reduced line pressure, this set cleans the shop air to 5 um, holds the regulated setting with the low-pressure type regulator, oils the downstream cylinders, and the check valve holds the circuit if supply dips.

science

Automotive paint and finishing lines

At spray booths and finishing stations, the 5 um element strips water and particulate before the air reaches guns and hoses, the regulator sets the lower working pressure the booth needs, and the lubricator is set to feed only the tool circuits that require it.

conveyor_belt

Packaging and bottling line air cylinders

On packaging machines with many small cylinders and actuators, one G1/2 supply point feeds filtered, regulated, lubricated air to the whole line, with the psi gauge giving operators a visible setting and the manual drain cleared during scheduled stops.

Is the AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain the Right Station?

Start with the size and port step: 200, 300, 400 and 600 correspond to increasing port sizes (here 1/2 in) and increasing flow capacity, so size up if your demand sits near the top of a smaller unit's curve. Choose the drain type: manual (as coded here) means someone opens the drain at intervals; automatic and differential-pressure drains are available on the family. Choose the filter grade: 40 um is the standard element and 5 um (code W, as here) is the finer option for more demanding downstream equipment. Choose the gauge and its scale (MPa, psi or bar); this unit carries a round psi gauge. Select the thread: PT is the standard, with G (BSPP) and NPT as order options - this unit is specified with G thread. A bracket is included, and the low-pressure type regulator suits circuits that operate at lower regulated pressures. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a l/min, m3/h or SCFM figure. Send us your inlet pressure and demand and we will confirm the datasheet flow figures for this size 400, G1/2 unit on request before you order.

The M in the code specifies a manual drain on the filter bowl: an operator opens it periodically to expel collected water. The family also offers an automatic drain (code A) and a differential-pressure drain (the default, blank code) if you would rather not rely on manual attention. The same drain choice applies to the filter bowls across the GC family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC40015MLC2WGK F.R.L. Unit, G1/2, 5 um, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015MLC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.