verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain

The AirTAC AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$198.89 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain

The AirTAC GC600-25G is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one coordinated set for compressed air. This configuration is built around a G1 (1 in) port with G thread, the largest step in the GC range, so it suits a main air line rather than a branch drop. The filter stage carries the standard 40 um element with a manual drain and an aluminium alloy bowl, which is the bowl material used at size 600. The regulator is the low-pressure type and is fitted with an embedded square gauge scaled in psi; a reverse/check valve is fitted, and a mounting bracket is included.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600, with port steps from 1/8 in up to 1 in, drain choices (differential-pressure, automatic or manual), an optional 5 um element (code W), gauge scales in MPa, psi or bar, and PT as the standard thread with G and NPT as order options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and flow figures for your application on request.

AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain Technical Specifications

ModelAirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain Is Used

factory

Automotive assembly plant main air line

Installed at the 1 in main drop feeding an assembly hall, the set cleans water and particulate from the plant air, holds a steady low-pressure supply to the tools and carries a fine oil mist to keep air impact wrenches and nut runners lubricated through the shift.

conveyor_belt

Bottling line conveyor and actuator supply

Mounted on the supply to a bottling hall conveyor system, the filter stage removes condensate and debris before the air reaches cylinders and grippers, the low-pressure regulator holds a stable setting for gentle product handling, and the lubricator mists the air for the line's pneumatic actuators.

engineering

Heavy fabrication shop pneumatic tool ring main

Fitted where a fabrication shop's 1 in ring main drops to tool stations, the unit conditions the air for grinders, chippers and clamps: the 40 um element and manual-drain bowl catch water and swarf, the regulator sets the working pressure at the station, and the lubricator feeds the shop's air tools.

Is the AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain the Right Station?

Start with the port step: size 600 with a 1 in port is the top of the range, so match it against the air demand of the line it will feed; smaller sizes (200/300/400) step down in port and physical size. Because flow is published as curves and not as a single rating, ask us to confirm sizing against your application before ordering. For the drain, this unit is manual: someone opens the drain periodically, which suits attended installations; automatic and differential-pressure drains are available in the family where unattended purging is preferred. The standard element is 40 um; specify code W for the 5 um grade if downstream equipment needs finer filtration. The gauge here is the embedded square type scaled in psi; MPa and bar scales and an external round gauge are alternatives. Thread is G in this code; PT is the standard and NPT can be ordered. A bracket is included with this set.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain FAQ

AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a l/min, m3/h or SCFM number. Size 600 with a 1 in port is the largest step in the GC range, which is usually the tell for a main-line unit, but the right check is against your actual demand. Send us your application details and we will confirm the flow figures from the datasheet on request before you order.

This code carries drain type M, a manual drain: the aluminium alloy bowl on the filter stage is emptied by opening the drain periodically, which suits installations where someone is present to do it. If the set will sit unattended, the GC family also offers automatic (code A) and differential-pressure (blank) drains, and the regulator adjustment range depends on the drain type fitted, so tell us your preference and we will confirm the right variant.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC600-25G F.R.L. Three-Unit, G1, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC60025MLF2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.