The AirTAC AirTAC GFC200-06 Combination Unit (GFC20006MC2WK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC20006MC2WK is a two-unit air-treatment set combining a filter regulator and a lubricator, with the K option adding a reverse (check) valve so downstream air is held if supply pressure is lost. It filters water and particulate, regulates outlet pressure and meters oil mist in one assembly. This configuration is the 200 size with PT1/8 ports, manual drain, a fine 5 um element and a round psi gauge.
This is a genuine AirTAC part. The GFC series runs from size 200 to 600 with ports from 1/8 to 1 inch, drain choices of differential-pressure, automatic or manual, 40 um or 5 um filtration, and PT, G or NPT threads. Max working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C (non-freezing). Flow is published as curves, not a single rating, so we confirm datasheet figures on request.
| Model | AirTAC GFC200-06 Combination Unit (GFC20006MC2WK) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-06 |
| Build order | Filter regulator first, lubricator last |
Regulated, filtered and oiled air powers hold-down clamps on a carton-sealing conveyor, with the check valve keeping clamps engaged through brief supply dips.
A service-bench drop feeding air ratchets and blow guns, where the 5 um element and oil mist extend tool life and the manual drain is emptied at shift end.
Clean, stable pilot pressure to pneumatic valve positioners on a small skid, with the check valve holding the pilot circuit if the main header loses pressure.
Match the 200/300/400/600 size to your port and flow band; 200 with PT1/8 suits compact point-of-use lines. The K code fits a check valve - useful when a cylinder must not retract or a bowl must not back-feed if supply drops. Keep the manual drain where someone drains bowls routinely, or move to an automatic-drain code for unattended positions. The 5 um W element is for finer protection; 40 um is the standard alternative. Round psi gauge here, with MPa or bar scales and G or NPT threads orderable.
Because published flow is a curve rather than one rated value, ask us to confirm sizing from the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.
There is no single rated flow figure to quote: AirTAC publishes G-series flow as performance curves. Tell us your working pressure and air demand and we will confirm the right size from the datasheet on request.
K is the reverse (check) valve option on the regulator side of the set: it blocks reverse flow so downstream pressure is retained if the upstream supply falls away. Codes without K have no check valve fitted.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.