The AirTAC AirTAC GFC200-06 Combination Unit (GFC20006MLN) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The GFC200 is the AirTAC two-piece air-treatment set: a filter regulator and a lubricator working together, so one purchase covers filtration, pressure regulation and oil-mist lubrication of compressed air. In this version the 06 code gives a PT1/8 port, M specifies a manual drain on the filter bowl (polycarbonate bowl at size 200), the element is the standard 40 um grade, and N means no gauge is fitted. L identifies the low-pressure regulator type for circuits set to lower pressures.
This is a genuine AirTAC part. The G series spans sizes 200 to 600 with ports from 1/8 in. up to 1 in., offering drain types (differential-pressure, automatic or manual), 40 um or 5 um (W) elements, gauge options and G (BSPP) or NPT thread versions. Flow is published as curves rather than a single rated figure, so we confirm datasheet figures for your application on request.
| Model | AirTAC GFC200-06 Combination Unit (GFC20006MLN) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-06 |
| Build order | Filter regulator first, lubricator last |
Treating the air that feeds the mini cylinders and light grippers on a carton taping or label-applying head, where the machine runs off a compact bench circuit with 1/8 in. tubing and lubricated air keeps the actuators moving freely.
Supplying filtered, regulated and lubricated air to light pick-and-place actuators on a PCB handling cell, with the 40 um element keeping water and particles out of small-bore lines and the low-pressure type matching a gentle setpoint.
A maintenance-bench outlet where treated air feeds die grinders and pneumatic screwdrivers; the lubricator mists oil into the tool supply and the manual drain suits stations that are bled down at the end of each shift.
Size 200 with a PT1/8 port is the smallest step in the G series; if your circuit draws more air than a 1/8 in. line can feed, step up to GFC300-08 (PT1/4) or larger. This unit has a manual drain, so an operator opens the bowl drain during checks; choose A for an automatic drain or leave the code blank for differential-pressure drain. The 40 um element is standard and W gives a 5 um element. Thread is PT as standard, with G (BSPP) and NPT available to order; max working pressure is 1.0 MPa (145 psi). Because this is the L low-pressure type, ask us to confirm the setting range for your setpoint. Flow is published as curves, not a single rating, so have us confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote one number here. Tell us your line pressure and air demand and we will confirm the sizing from the datasheet on request.
The M code gives a manual drain: someone opens the filter bowl drain during inspection or shutdown. If the set sits where nobody walks past, order the A version with an automatic drain, or leave the drain code blank for the differential-pressure default.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.