
The AirTAC AirTAC GFC200-06 Combination Unit (GFC20006MN) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The GFC200 is the AirTAC two-piece air-treatment set: a filter regulator and a lubricator working together, so one purchase covers filtration, pressure regulation and oil-mist lubrication of compressed air. In this version the 06 code gives a PT1/8 port, M specifies a manual drain on the filter bowl (polycarbonate bowl at size 200), the element is the standard 40 um grade, the regulator is the standard type, and N means no gauge is fitted.
This is a genuine AirTAC part. The G series spans sizes 200 to 600 with ports from 1/8 in. up to 1 in., offering drain types (differential-pressure, automatic or manual), 40 um or 5 um (W) elements, gauge options and G (BSPP) or NPT thread versions. Flow is published as curves rather than a single rated figure, so we confirm datasheet figures for your application on request.
| Model | AirTAC GFC200-06 Combination Unit (GFC20006MN) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-06 |
| Build order | Filter regulator first, lubricator last |
Treating the supply to the small cylinders and air jets on a wrapping or cartoning machine, where a two-piece set at the 1/8 in. machine inlet filters, regulates and oils the air in one stop.
Feeding treated air to pneumatic cutters, dancers and capstan helpers on a wire-processing line, with the 40 um element and lubricator keeping small actuators clean and running on oiled air.
A service-bay drop where treated air feeds impact drivers and blowguns; the manual drain suits outlets that are drained as part of end-of-day housekeeping.
Size 200 with a PT1/8 port is the smallest step in the G series; step up to GFC300-08 (PT1/4) or larger if your demand outgrows a 1/8 in. line. This unit has a manual drain, so plan on someone opening the bowl drain during checks; A gives an automatic drain and blank gives the differential-pressure default. The 40 um element is the standard grade and W upgrades to 5 um. With the N code no gauge is fitted; gauge-equipped versions are available if you want a visible setpoint at the unit. Thread is PT as standard, with G (BSPP) and NPT available to order; max working pressure is 1.0 MPa (145 psi) and the standard-type regulator with manual drain adjusts from 0.05-0.9 MPa (7-130 psi). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote one number here. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request.
A GFC set pairs a filter regulator with a lubricator in two units, while a GC combination keeps the filter, regulator and lubricator as three separate bodies. The GFC takes less wall space and fewer joints; choose the GC if you want each function serviced or repositioned independently.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.