The AirTAC AirTAC GFC200-06 Combination Unit (GFC20006MNWK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC series is a two-unit air preparation set: a filter regulator plus a lubricator, giving filtration, pressure regulation and oil-mist lubrication in one station. This GFC20006MNWK is the 200 size with PT 1/8 ports, a manual drain on the filter bowl, a 5 um filter element, no gauge fitted, and a reverse (check) valve specified by the trailing K. The manual drain means water is emptied from the bowl by hand, and the 5 um element captures finer particulate than the standard 40 um grade. Downstream pressure is set on the regulator within the manual-drain range of 0.05-0.9 MPa (7-130 psi), with a maximum working pressure of 1.0 MPa (145 psi).
This is a genuine AirTAC part. The G series comes in 200, 300, 400 and 600 sizes with ports from 1/8" to 1", 40 um standard or 5 um (W) filter grades, differential-pressure, automatic or manual drains, gauge options, and PT, G or NPT threads. Working temperature is -5 to 70 C (non-freezing) and the 200-size bowls are polycarbonate. Flow is published as curves rather than a single rating, so we confirm datasheet and flow figures for your circuit on request.
| Model | AirTAC GFC200-06 Combination Unit (GFC20006MNWK) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-06 |
| Build order | Filter regulator first, lubricator last |
In a fixture-clamping circuit on an assembly cell, the regulator holds the clamp pressure and the specified check valve addresses circuits where reverse flow must be prevented; the lubricator feeds the clamp cylinders.
On a pick-and-place gantry with gripper cylinders and vacuum ejector feeds, this set conditions the branch line: 5 um filtration, regulated pressure at each station and oil mist for the actuators.
At a small pneumatic bench press, the set sits at the drop: the regulator sets working pressure, the 5 um element protects the valve stack, and the lubricator conditions the press cylinder.
Step up from 200 to 300, 400 or 600 when your circuit needs larger ports and more flow; this 200 size with PT 1/8 ports suits compact circuits. The trailing K specifies a reverse (check) valve with the unit; the same code without K is the standard build. The manual drain (M) suits stations where an operator can empty the bowl during checks; automatic (A) and the default differential-pressure drain are also offered. Keep the W code for the 5 um element or drop it for 40 um. No gauge is fitted on this code; square embedded and round external gauges with MPa, psi or bar scale are available in other variants. PT is the standard thread, with G (BSPP) and NPT as catalogue options. Flow is published as curves, not a single rating - ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.
AirTAC publishes flow for the G series as characteristic curves rather than a single rated figure, so there is no one number to quote. Send us your circuit details and we will confirm the datasheet curve and check the 200 size with PT 1/8 ports against your application before ordering.
K specifies a reverse (check) valve fitted with the unit; the equivalent code without K, GFC20006MNW, has none. Everything else decodes identically: 200 size, PT 1/8 ports, manual drain, 5 um element and no gauge. If you prefer hands-off water removal, ask about the A-drain variant.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.