verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC200-06 Combination Unit (GFC20006NW)

The AirTAC AirTAC GFC200-06 Combination Unit (GFC20006NW) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$45.70 $50.52Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC200-06 drain, gauge and thread option on one page All GFC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC200-06 Combination Unit (GFC20006NW)

GFC20006NW is a genuine AirTAC two-unit air-treatment set: a filter regulator combined in one body, paired with a lubricator, so one setup filters, regulates and oil-mist lubricates compressed air. This configuration is the 200 size with a PT1/8 port, the standard differential-pressure drain, the finer 5 um (W) filter element instead of the standard 40 um, and no gauge (N). Regulation range with the differential-pressure drain is 0.15-0.9 MPa (20-130 psi); maximum inlet pressure is 1.0 MPa (145 psi). Both bowls on the 200 size are polycarbonate (PC), and the working temperature range is -5 to 70 C (non-freezing).

AirTAC builds the G series in 200, 300, 400 and 600 sizes with ports from 1/8 in up to 1 in and PT, G (BSPP) or NPT threads. Drain style, 40 um or 5 um filtration, gauge and scale choices and mounting options let you match the set to the job. Flow for the series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet and flow figures for GFC20006NW on request.

AirTAC GFC200-06 Combination Unit (GFC20006NW) Technical Specifications

ModelAirTAC GFC200-06 Combination Unit (GFC20006NW)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-06 Combination Unit (GFC20006NW)

GFC200G-series two-unit set, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/8" · 5 µm
One size upGFC300
Three-unit equivalentGC200-06
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-06 Combination Unit (GFC20006NW) Is Used

settings_input_component

Compact packaging machinery

Feeds clean, regulated and lubricated air to small solenoid valves and mini cylinders on carton-sealing and labelling heads, where the 5 um element protects fine valve internals and the lubricator keeps cylinder seals working.

precision_manufacturing

Small assembly stations

Supplies air to light-duty grippers and pick-and-place actuators on electronics and small-part assembly benches, holding a steady set pressure from the 1/8 in supply line.

handyman

Bench air-tool drops

Conditions the air at a workbench drop for air screwdrivers, riveters and small impact tools, filtering water and particles, stabilising pressure and carrying oil mist to the tool.

Is the AirTAC GFC200-06 Combination Unit (GFC20006NW) the Right Set?

The 200 size with a PT1/8 port is the entry step of the G series; if your line draws more air, step up to 300, 400 or 600 with the matching larger port. Filtration here is the 5 um (W) element for finer protection of downstream valves; the standard 40 um element suits general machine supply. Drain is the differential-pressure type; order automatic (A) for unattended draining or manual (M) for serviced points, which also widens the regulation range to 0.05-0.9 MPa. No gauge is fitted on this code (N); square and round gauges in MPa, psi or bar scales are catalogue options. Thread is PT as standard, with G (BSPP) and NPT available to order. Flow is published as curves, not a single rating, so send us your air demand and we will confirm sizing against the application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.

AirTAC GFC200-06 Combination Unit (GFC20006NW) FAQ

AirTAC publishes G-series flow as curves, not as a single rated number, so no rated flow figure is quoted here. Send us your line pressure and air demand and we will confirm the datasheet and flow curve for this exact two-unit set on request.

GFC combines the filter and regulator in one body and pairs it with a lubricator, so you get filtering, regulation and lubrication in two pieces instead of three - fewer joints, less mounting space and simpler installation. A three-piece GC keeps each stage separate when you prefer to service units individually.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC200-06 Combination Unit (GFC20006NW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC20006NW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.