The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008F2) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit air preparation set: a filter-regulator in one body, paired with a separate lubricator. This GFC20008F2 is the size 200 frame with 1/4 in PT ports. It filters water and particulate down to the standard 40 um grade, regulates downstream pressure over 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain, then adds oil-mist lubrication for downstream air tools and cylinders. The embedded square pressure gauge is scaled in psi, so setpoints can be read directly without conversion.
This is a genuine AirTAC part. The G series runs in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades, gauges and PT, G or NPT threads; the 200-size bowls are polycarbonate. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008F2) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Filter, regulate and lubricate the air feeding atomising spray guns on a 1/4 in drop, keeping water, particles and a controlled oil mist in the supply line.
Condition the air to small packaging-machine cylinders, grippers and diverters on 1/4 in branch lines, with the pressure set on a direct-reading psi gauge.
Feed impact drivers, die grinders and ratchets at individual benches with filtered, pressure-set, lubricated air from the shop ring main.
Size 200 with 1/4 in ports suits compact branch lines; step up to GFC300, GFC400 or GFC600 when the circuit carries more flow. The differential-pressure drain is the default here, and automatic (A) or manual (M) drain versions can be ordered if your duty needs them. The square gauge is supplied in the psi scale you asked for, while MPa and bar scales are catalogue alternatives. PT is the standard thread; G (BSPP) and NPT are options to order, and a mounting bracket is included.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
AirTAC publishes G-series flow as performance curves rather than one rated figure, and we do not quote a single number. Tell us your line pressure and demand and we will confirm the sizing from the datasheet curves before you order.
Yes. On this model the square gauge is the psi (scale 2) version. MPa (scale 1) and bar (scale 3) versions are catalogue options, so you can match the gauge to the units your operators work in.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.