The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008LC1) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit air preparation set: a filter-regulator in one body, paired with a separate lubricator. This GFC20008LC1 is the size 200 frame with 1/4 in PT ports, built in the low-pressure type for circuits that run below standard line pressure. It filters water and particulate with the standard 40 um grade, regulates the downstream pressure, and adds oil-mist lubrication. The gauge is the external round version, scaled in MPa.
This is a genuine AirTAC part. The G series runs in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades, gauges and PT, G or NPT threads; the 200-size bowls are polycarbonate. Flow figures and the exact adjustment range of the low-pressure type are confirmed from the datasheet on request.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008LC1) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Supply low-pressure conditioned air to pneumatic test fixtures and leak-check stations in the workshop or lab, with the MPa reading taken from the external round gauge.
Feed low-pressure purge and cooling air to enclosures and sensor heads, filtered and regulated below the standard pressure band.
Run the pneumatic tuck-and-fold heads on a carton sealing line at reduced pressure, with filtered and lubricated air on a 1/4 in branch.
Pick the L (low-pressure) type when your circuit runs at reduced pressure rather than the standard regulator range; ask us to confirm its adjustment range against your setpoint before ordering. Size 200 with 1/4 in ports fits compact branch lines, with GFC300 to GFC600 available for larger flows. The differential-pressure drain is the default and automatic (A) or manual (M) versions can be ordered. The round external gauge is in the MPa scale, with square-gauge and other scale options in the catalogue. PT is the standard thread; G (BSPP) and NPT are options to order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated figure, and the low-pressure type's adjustment band differs from the standard version. Send us your setpoint and demand and we will confirm both from the datasheet on request.
In the GFC, the filter and regulator share a single body with the lubricator as the second unit, so the set is more compact and simpler to mount than the GC, which keeps filter, regulator and lubricator as three separate bodies. Both deliver filter, regulation and lubrication; the choice is footprint and layout.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.