The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008LN) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC20008LN is a genuine AirTAC G-series two-unit set: a filter-regulator plus a separate lubricator, delivering filtered, regulated and lubricated compressed air in one assembly. This configuration is size 200 with a PT1/4 port, uses the standard 40 um filter element, drains condensate by differential pressure, is the low-pressure regulator type, and has no gauge fitted. Both bowls are polycarbonate. Medium is compressed air only, maximum working pressure is 1.0 MPa (145 psi), and operating temperature is -5 to 70 C, non-freezing. With differential-pressure draining, the regulator adjust range is 0.15-0.9 MPa (20-130 psi).
AirTAC builds the GFC family in sizes 200, 300, 400 and 600, with a choice of differential-pressure, automatic or manual drains, 40 um or 5 um (W) filter elements, standard or low-pressure regulation, and gauge options; PT is the standard thread with G (BSPP) and NPT as catalogue options. Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008LN) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Feeding regulated, lubricated air to pick-and-place grippers and clamp cylinders on a carton-forming packaging line, with the lubricator protecting cylinder seals through continuous duty.
Supplying filtered, regulated, oil-misted air to impact drivers and nut runners at assembly benches where tool manufacturers require a lubricated supply for warranty cover.
Running pneumatic diverters, pushers and stop gates on a distribution conveyor, with the regulator holding a steady setting shift after shift and the filter shedding line-scale and water.
Size 200 with a PT1/4 port suits circuits whose demand matches the 200 frame; step up to 300, 400 or 600 for larger ports and more flow. The differential-pressure drain is the default here; automatic (A) suits unattended drains and manual (M) suits scheduled service - note that drain choice affects the regulator adjust range. The 40 um element is standard; specify W for 5 um filtration. Gauge options are the embedded square gauge or an external round gauge in MPa, psi or bar scales, and this N-coded version comes without any gauge. PT is standard; G and NPT are order options.
Because flow is published as curves and not a single rated figure, we cannot honestly quote one number for this set. Send us your line pressure and air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
AirTAC publishes flow for the G series as curves rather than a single rated figure, so no single number honestly describes this set. Send us your inlet pressure, port size and downstream demand and we will confirm the datasheet curve and correct sizing before you order.
The code ends in N, so no gauge is fitted; an embedded square gauge or an external round gauge in MPa, psi or bar scale can be specified instead. LN also marks the low-pressure regulator type - tell us your set pressure and we will confirm the adjust range that applies to your drain choice.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.