AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC200-08 Combination Unit (GFC20008LN)

The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008LN) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$45.70 $50.52Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC200-08 drain, gauge and thread option on one page All GFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC200-08 Combination Unit (GFC20008LN)

GFC20008LN is a genuine AirTAC G-series two-unit set: a filter-regulator plus a separate lubricator, delivering filtered, regulated and lubricated compressed air in one assembly. This configuration is size 200 with a PT1/4 port, uses the standard 40 um filter element, drains condensate by differential pressure, is the low-pressure regulator type, and has no gauge fitted. Both bowls are polycarbonate. Medium is compressed air only, maximum working pressure is 1.0 MPa (145 psi), and operating temperature is -5 to 70 C, non-freezing. With differential-pressure draining, the regulator adjust range is 0.15-0.9 MPa (20-130 psi).

AirTAC builds the GFC family in sizes 200, 300, 400 and 600, with a choice of differential-pressure, automatic or manual drains, 40 um or 5 um (W) filter elements, standard or low-pressure regulation, and gauge options; PT is the standard thread with G (BSPP) and NPT as catalogue options. Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.

AirTAC GFC200-08 Combination Unit (GFC20008LN) Technical Specifications

ModelAirTAC GFC200-08 Combination Unit (GFC20008LN)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-08 Combination Unit (GFC20008LN)

GFC200G-series two-unit set, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/4" · 40 µm
One size upGFC300
Three-unit equivalentGC200-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-08 Combination Unit (GFC20008LN) Is Used

precision_manufacturing

Packaging gripper and clamp cylinders

Feeding regulated, lubricated air to pick-and-place grippers and clamp cylinders on a carton-forming packaging line, with the lubricator protecting cylinder seals through continuous duty.

handyman

Assembly-cell air tools

Supplying filtered, regulated, oil-misted air to impact drivers and nut runners at assembly benches where tool manufacturers require a lubricated supply for warranty cover.

conveyor_belt

Conveyor diverters and stop gates

Running pneumatic diverters, pushers and stop gates on a distribution conveyor, with the regulator holding a steady setting shift after shift and the filter shedding line-scale and water.

Is the AirTAC GFC200-08 Combination Unit (GFC20008LN) the Right Set?

Size 200 with a PT1/4 port suits circuits whose demand matches the 200 frame; step up to 300, 400 or 600 for larger ports and more flow. The differential-pressure drain is the default here; automatic (A) suits unattended drains and manual (M) suits scheduled service - note that drain choice affects the regulator adjust range. The 40 um element is standard; specify W for 5 um filtration. Gauge options are the embedded square gauge or an external round gauge in MPa, psi or bar scales, and this N-coded version comes without any gauge. PT is standard; G and NPT are order options.

Because flow is published as curves and not a single rated figure, we cannot honestly quote one number for this set. Send us your line pressure and air demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.

AirTAC GFC200-08 Combination Unit (GFC20008LN) FAQ

AirTAC publishes flow for the G series as curves rather than a single rated figure, so no single number honestly describes this set. Send us your inlet pressure, port size and downstream demand and we will confirm the datasheet curve and correct sizing before you order.

The code ends in N, so no gauge is fitted; an embedded square gauge or an external round gauge in MPa, psi or bar scale can be specified instead. LN also marks the low-pressure regulator type - tell us your set pressure and we will confirm the adjust range that applies to your drain choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC200-08 Combination Unit (GFC20008LN)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC20008LN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.