The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008MC2) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC series is a two-unit air preparation set: a filter-regulator body plus a separate lubricator, supplying filtered, regulated and lubricated air from one assembly. This configuration, the GFC20008MC2, is the 200 size with a PT1/4 port. The M code gives a manual drain on the filter bowl, the standard 40 um filter element is fitted, and the C2 code adds the external round pressure gauge reading in psi.
This is a genuine AirTAC part in the G range, which runs from size 200 up to 600 with larger ports and higher flow. Bowls on 200/300/400 sizes are polycarbonate. Medium is compressed air, maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C. Flow figures are published as curves rather than a single rating, so we confirm the datasheet numbers for your application on request.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008MC2) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Regulated, lubricated air for the diverter gates and stopper cylinders along a warehouse parcel-sorting conveyor.
A wall-mounted preparation point giving filtered, oil-misted air to pneumatic nutrunners and impact drivers at a maintenance bay.
Set-pressure air for the lift and lip cylinders and control valves on a pneumatic dock leveller at a loading bay.
The 200 size with a 1/4" port fits compact supply points; move to 300/400/600 when demand grows, since each step raises port size and flow. This version keeps the standard 40 um element, ideal for general-purpose circuits - specify the W code instead if you need the finer 5 um grade. Manual drain suits attended machines; automatic (A) or the differential-pressure default suits unattended ones. The C2 round gauge reads in psi, handy for US-style pressure setting; MPa and bar scales are on other variants. PT thread is the standard, and G(BSPP) or NPT are catalogue options to order. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
There is no single rated-flow figure we can quote: AirTAC publishes G-series flow as curves, and our Category facts do not include one. Give us your working pressure and consumption and we will confirm the right size from the datasheet on request before you order.
The 40 um element on this set is the standard grade for general supply to cylinders and air tools. For pilot valves, precision actuators or coating equipment, choose the W-coded 5 um version of the same GFC set - same body and function, finer element.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.