The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008MF1K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The GFC20008MF1K is an AirTAC GFC two-unit set: a filter-regulator plus a lubricator that together filter, regulate and oil-mist lubricate compressed air. This configuration is size 200 with a 1/4 in. PT port, the standard 40 um filter element with a manual drain, an embedded square MPa gauge, and a reverse (check) valve fitted so the set also helps hold downstream pressure if supply pressure drops.
It is a genuine AirTAC part for compressed air, rated to 1.0 MPa (145 psi) maximum working pressure and -5 to 70 C (non-freezing), with polycarbonate bowls at this size. Because the drain is manual, the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). Sizes 200 to 600 and further options exist in the G series; we confirm flow curves and datasheet figures on request.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008MF1K) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
The fitted reverse (check) valve helps hold downstream pressure in a fixture-clamping circuit if supply pressure dips, so jigs keep their set state between cycles.
A filtered, regulated and lubricated service drop for impact wrenches and ratchets in a plant maintenance bay, with the gauge showing regulated line pressure.
Conditioned air for the gripper and wrist cylinders of a pick-and-place robot, combining clean regulated supply with oil-mist lubrication for the actuator pack.
Size 200 with a 1/4 in. PT port covers lighter-duty circuits; move to size 300 (3/8 in.) or 400 (1/2 in.) when the circuit needs more flow. Drain options are differential-pressure (default), automatic (A) or manual (M, this unit). The standard element is 40 um; order the W suffix for 5 um. The K suffix adds the reverse/check valve fitted here - omit it when backflow holding is not needed. PT is the standard thread; G (BSPP) and NPT are catalogue options, and the gauge can be MPa, psi or bar scale. Flow is published as curves rather than a single rating, so let us confirm sizing against your application before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
There is no single rated figure to quote: AirTAC publishes G-series flow as performance curves. We will confirm the curve for this size 200 set from the datasheet on request so you can check it against your consumption.
K marks a reverse (check) valve fitted to the set, which helps hold downstream pressure if supply pressure drops. The rest of the code decodes as size 200, PT1/4 port, manual drain, standard 40 um element and an embedded square MPa gauge.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.