The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008MLN) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
GFC20008MLN is an AirTAC G-series two-unit set: a filter-regulator paired with a lubricator, so one unit removes water and coarse particulate and holds a set pressure while the other meters oil mist to downstream cylinders and air tools. This PT1/4 (1/4 inch) configuration is the low-pressure (L) type with a manual drain bowl and no gauge (N code), for machines that carry their own panel instrument or need no local readout. Maximum working pressure is 1.0 MPa (145 psi), and with the manual drain the regulator adjusting range is 0.05-0.9 MPa (7-130 psi). Operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFC series spans 200/300/400/600 sizes with ports from 1/8 to 1 inch; at 200 size the bowls are polycarbonate (600 size is aluminium alloy), and drain type, filter grade, gauge scale and thread are selectable options. Flow figures for G-series units are published as curves rather than a single rating, so we confirm the datasheet and sizing figures on request.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008MLN) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Fitting at the outlet of workshop air drops that already have a master panel gauge: the set filters, regulates and lubricates at the point of use for impact wrenches and air ratchets, with no duplicate instrument at the drop.
Building into machines where the OEM wires its own pressure indication in the control cabinet: this gauge-less two-unit set conditions air to solenoid valves and actuators while the cabinet instrumentation handles all readouts.
Supplying clamping cylinders on machining jigs and welding fixtures: the low-pressure type holds a repeatable set pressure, the 40 um element protects the directional valves, and the lubricator keeps the clamp cylinders sealed and smooth.
Choose the size by port and air demand: the 200 body with 1/4 inch PT ports suits compact supply drops, with 300/400/600 for larger lines. Drain choices are differential-pressure (default), automatic or manual; this unit has manual drain, giving the widest quoted adjusting range of 0.05-0.9 MPa (7-130 psi). Filter grade is the 40 um standard, with a 5 um W option available. This version carries no gauge; if you want a local readout, order the gauge-coded variants with the embedded square gauge in MPa, psi or bar scale. Thread is PT as standard with G (BSPP) and NPT as catalogue options. Flow is published as curves, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
Flow for this series is published as curves rather than a single rated figure, so we cannot give one l/min or SCFM number here. Tell us your supply pressure, downstream demand and port size and we will confirm the sizing against the datasheet curves on request before you order.
The N code deletes the local gauge for machines that carry their own panel instrument or need no readout. You adjust the regulator with the reference instrument you already have. If you later want a local display, the same 200-size body is available with the embedded square gauge in MPa, psi or bar scale under separate catalogue codes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.