verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC200-08 Combination Unit (GFC20008MLNW)

The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008MLNW) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$45.70 $50.52Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC200-08 drain, gauge and thread option on one page All GFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC200-08 Combination Unit (GFC20008MLNW)

The AirTAC GFC series is a two-piece air-treatment set: a filter regulator (which removes water and particulate and sets downstream pressure in one body) paired with a separate lubricator that adds an oil mist to the air line. This configuration is the 200 size with a 1/4 in PT port, a manual drain on the filter bowl, a fine 5 um filter element (W grade), the low-pressure (L) regulator type with an adjustment range up to 0.4 MPa, and no gauge fitted. With no gauge on board, pair it with your own instrumentation or ask us about gauge options on other variants.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 (larger size means larger port and more flow), with a choice of 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, gauge options, and PT (standard), G (BSPP) or NPT threads. Published flow data appears as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.

AirTAC GFC200-08 Combination Unit (GFC20008MLNW) Technical Specifications

ModelAirTAC GFC200-08 Combination Unit (GFC20008MLNW)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-08 Combination Unit (GFC20008MLNW)

GFC200G-series two-unit set, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/4" · 5 µm
One size upGFC300
Three-unit equivalentGC200-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-08 Combination Unit (GFC20008MLNW) Is Used

precision_manufacturing

Low-pressure pneumatic clamping on assembly fixtures

Mounted at the drop to a clamping fixture that must run at reduced pressure, this set filters water and fine particles, holds the set pressure with the low-pressure regulator, and mists oil to the cylinder seals - the manual drain suits a shift-start maintenance routine.

science

Air supply to laboratory actuated valves

On a lab skid where pilot air feeds small actuated valves, the 5 um element keeps fine debris out of pilot circuits while the lubricator protects moving valve internals; the low-pressure type matches a gentle supply pressure.

build

Bench air for jig and tooling stations

At a manual workbench running air tools and jigs, the filter regulator cleans and sets the supply while the lubricator keeps tool motors running smoothly; the 1/4 in port and manual drain fit a compact, operator-serviced point of use.

Is the AirTAC GFC200-08 Combination Unit (GFC20008MLNW) the Right Set?

Start with the size and port: this 200-size unit has a 1/4 in PT port, so step up to 300, 400 or 600 if your line demands more flow. The manual drain here means an operator opens the bowl drain periodically - if you want unattended condensate removal, choose automatic (A) or the differential-pressure default instead. The 5 um element (W) suits finer point-of-use protection; the 40 um standard element is the usual general-line choice. This variant carries no gauge; gauge and scale options exist on other GFC codes. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options; a bracket is optional.

Because flow is published as curves rather than one rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.

AirTAC GFC200-08 Combination Unit (GFC20008MLNW) FAQ

AirTAC publishes air-treatment flow as curves rather than a single rated figure, so we do not quote one number here. Tell us your application and we will confirm the flow figures from the datasheet for this 200-size, 1/4 in unit on request.

The N in the code means no gauge is fitted on this variant; gauge and scale options are available on other GFC codes. This set uses a manual drain, which suits stations where an operator drains the bowl regularly - choose automatic (A) or the differential-pressure default for unattended lines.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC200-08 Combination Unit (GFC20008MLNW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC20008MLNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.