The AirTAC AirTAC GFC200-08 Combination Unit (GFC20008NW) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC20008NW is an AirTAC GFC two-unit air-preparation set: a filter regulator and a lubricator paired to deliver filtered, regulated and lubricated compressed air through a PT1/4 (1/4 inch) port. This code specifies the differential-pressure drain (default), the fine 5 um (W) filter element, the standard regulator type, and no gauge (N). With the differential-pressure drain, the regulator adjustment range is 0.15-0.9 MPa (20-130 psi); maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C. The bowls on this size 200 set are polycarbonate (PC).
This is a genuine AirTAC G-series part. The GFC family is offered in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, automatic, manual or differential-pressure drain options, 40 um or 5 um elements, G (BSPP) and NPT thread options, and gauge options. Flow is published as curves rather than a single rating, so we confirm sizing and datasheet figures on request.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008NW) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Feeds bench-top analysers and sampling instruments with filtered, regulated and lubricated air, using the 5 um element where finer cleanliness is wanted.
Conditions the supply to small actuation cylinders on an assembly cell, holding a consistent regulated pressure with lubricated, filtered air.
Prepares air for test-fixture clamps and lifters on an electronics line, where the finer 5 um element supports cleaner air at the point of use.
Size 200 with a PT1/4 port suits 1/4 inch pneumatic circuits; move to a 300/400/600 set when demand outgrows that line. Drain choice: the differential-pressure default here needs no drain fitting or operator attention; automatic (A) drains unattended and manual (M) allows hands-on bleeding with a wider 0.05-0.9 MPa (7-130 psi) regulator range. Filter grade: the 5 um (W) element here for finer particle removal; 40 um is the standard element. Thread is PT as the standard, with G (BSPP) and NPT as catalogue options. This code specifies no gauge (N); gauge options exist for the family. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not state one number. Send your operating pressure and air demand and we will confirm the right size against the datasheet on request before you order.
W in the code selects the finer 5 um element, used where cleaner air matters at the point of use; the blank default is 40 um for general plant air. Both are catalogue options on the same GFC sets, so pick by application, not by pressure rating.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.