The AirTAC AirTAC GFC300-08 Combination Unit (GFC30008ALF1W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-piece air preparation set: a filter regulator that removes water and particulate from compressed air and holds downstream pressure, paired with a separate lubricator that adds an oil mist for air tools. This configuration is the 300 size with PT1/4 ports, an automatic drain that ejects collected condensate without manual attention, a finer 5 um filter element, the L low-pressure regulator type, and an embedded square gauge scaled in MPa. The L suffix marks the low-pressure type; with the automatic drain the quoted adjust range is 0.15-0.9 MPa (20-130 psi), and we confirm the exact low-pressure span on request. Maximum working pressure is 1.0 MPa (145 psi), and the service temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part, supplied by airtacdistr.com across the 200/300/400/600 sizes with 1/8" to 1" ports, PT as the standard thread and G (BSPP) or NPT as order options. Across the series you can choose filter grade 40 um standard or 5 um with W, a differential-pressure, automatic or manual drain, and gauge or no-gauge variants. Because rated flow is published as curves rather than a single figure, we confirm datasheet and flow data for your application on request.
| Model | AirTAC GFC300-08 Combination Unit (GFC30008ALF1W) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/4" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-08 |
| Build order | Filter regulator first, lubricator last |
Conditioning, regulating and lubricating the supply to pick-and-place gripper cylinders on an electronics assembly cell, with the 5 um element protecting fine seals.
Filtering, regulating and oil-misting air to filler and capper cylinders on a beverage bottling conveyor, with the automatic drain coping with condensate between shifts.
Supplying regulated, lubricated air to impact drivers and nutrunners at an automotive trim bench, keeping tools fed with clean, oil-misted air at a set pressure.
Step up or down by size - 200, 300, 400, 600 - to match the flow your line needs and the port it takes; this set is size 300 with PT1/4 ports. Choose the drain style: automatic (fitted here) for unattended condensate removal, manual for periodic draining, or differential-pressure as the default. Pick 40 um for general supply or 5 um (W suffix) for finer protection downstream - this unit carries 5 um. Gauges come as the embedded square type in MPa, psi or bar scales, or you can order an N variant with no gauge. PT is the standard thread; order G or NPT where the installation specifies. Flow is published as curves, not one rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.
AirTAC publishes flow for the GFC series as characteristic curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the relevant curve and datasheet figures on request before you order.
A GFC combines the filter and regulator in one body and adds a separate lubricator, so you mount two components instead of three, with fewer joints and less panel space, while still filtering, regulating and lubricating. A GC keeps all three units separate, which suits layouts that want each element positioned independently.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.