The AirTAC AirTAC GFC300-08 Combination Unit (GFC30008ALN) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$72.04 $77.51Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC300-08 Combination Unit (GFC30008ALN)

The GFC series pairs a filter regulator - removing water and particulate from compressed air while holding downstream pressure - with a separate lubricator that meters an oil mist to air tools. This version is the 300 size with PT1/4 ports, an automatic drain that clears condensate without attention, the standard 40 um filter element, the L low-pressure regulator type, and the N option with no gauge fitted. The L suffix marks the low-pressure type; with the automatic drain the quoted adjust range is 0.15-0.9 MPa (20-130 psi), and we confirm the exact low-pressure span on request. Maximum working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part from airtacdistr.com, available across the 200/300/400/600 sizes with 1/8" to 1" ports, PT as standard and G (BSPP) or NPT as order options. Filter grade is 40 um standard or 5 um with W, drains come as differential-pressure, automatic or manual, and gauge-equipped variants exist where a local pressure readout is wanted. Because rated flow is published as curves, not a single figure, we confirm datasheet data on request.

AirTAC GFC300-08 Combination Unit (GFC30008ALN) Technical Specifications

ModelAirTAC GFC300-08 Combination Unit (GFC30008ALN)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-08 Combination Unit (GFC30008ALN)

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-08 Combination Unit (GFC30008ALN) Is Used

handyman

Woodshop nailer drop

Filtering, regulating and lubricating the branch feeding nailers and staplers at a furniture workshop bench, with the automatic drain handling overnight condensate.

view_module

Parcel sorter diverter supply

Conditioning air to the diverter and pusher cylinders on a parcel-sort conveyor, where pressure is read at the room's main panel rather than at each unit.

science

Lab automation actuators

Supplying clean, regulated, oil-misted air to the gripper and lift cylinders of a laboratory sample-handling station built into a closed cabinet.

Is the AirTAC GFC300-08 Combination Unit (GFC30008ALN) the Right Set?

Pick the size - 200, 300, 400 or 600 - for the flow and port your circuit requires; this unit is size 300 on PT1/4. Drain types are automatic (fitted here), manual, and the differential-pressure default. Filtration is the standard 40 um; order the W variant for 5 um where finer protection matters. The N code means no gauge, ideal for concealed panels or circuits that read pressure elsewhere - choose a square-gauge code in MPa, psi or bar scales when a local readout helps. PT is the standard thread, with G and NPT available to order. Flow is published as curves rather than one rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

AirTAC GFC300-08 Combination Unit (GFC30008ALN) FAQ

Flow for the GFC series is published as characteristic curves, not as a single rated figure, so we do not state a number here. Share your application - the devices served and their air demand - and we will confirm the datasheet curve and sizing on request before you order.

N is the no-gauge code: the regulator is supplied without a pressure gauge, which suits panels that display pressure elsewhere. Gauge-equipped variants use the embedded square gauge in MPa, psi or bar scales, so you can switch codes whenever a local readout is wanted.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC300-08 Combination Unit (GFC30008ALN)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC30008ALN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.