The AirTAC AirTAC GFC300-08 Combination Unit (GFC30008C3W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC30008C3W is a two-piece air-treatment set from AirTAC's G series: a size 300 filter regulator paired with a size 300 lubricator on 1/4 in PT ports. The W code fits the finer 5 um filter element, which traps smaller particulate than the standard 40 um grade - useful ahead of pilot valves, gauges and close-tolerance tooling. Condensate collects in a polycarbonate bowl with a differential-pressure drain, the regulator adjusts from 0.15-0.9 MPa (20-130 psi), and the lubricator meters oil mist downstream. Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing. This configuration includes an external round gauge reading in bar.
This is a genuine AirTAC part. The G two-piece sets span sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in; options include manual or automatic drains, the 40 um standard element, gauge scales in MPa, psi or bar, and G (BSPP) or NPT threads instead of PT. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.
| Model | AirTAC GFC300-08 Combination Unit (GFC30008C3W) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/4" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-08 |
| Build order | Filter regulator first, lubricator last |
Conditions the purge and actuation air feeding sample valves and pneumatic conveyors inside an on-line process analyser shelter. The 5 um element keeps fine pilot passages clear where the standard 40 um grade would let smaller particles through.
Feeds the vacuum ejectors and air cylinders on a PCB pick-and-place gantry. Finer 5 um filtration protects the small ejector nozzles, the regulator holds consistent placement pressure, and the lubricator services the slide cylinders.
Conditions the supply to pneumatic transmitters and I-to-P pilot valves on a batching and dosing plant. The 5 um grade suits the tight internal clearances of instrument-grade devices, with regulated and lubricated air downstream.
Choose this code when the job needs the 5 um element (code W) rather than the 40 um standard grade - for example ahead of pneumatic instrumentation or fine pilot valves. Size 300 with 1/4 in PT ports is the mid step of the range; step to size 400 if demand runs high. Drain: differential-pressure here (standard), automatic (A) or manual (M) as codes - manual drain widens the regulator range to 0.05-0.9 MPa (7-130 psi). This code carries a round gauge in bar; psi and square-MPa variants exist as separate codes. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options; a mounting bracket is optional. Because flow is published as curves and not a single rating, send us your demand figures and we will confirm sizing before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.
AirTAC publishes G-series flow as performance curves, not as a single rated figure, so we do not state one number here. Tell us your operating pressure and air consumption and we will check the datasheet curve and confirm the sizing on request before you order.
Use the 5 um grade when the equipment downstream has fine passages that 40 um particles could foul - pilot valves, instrumentation, small ejectors and close-tolerance air tools. For general cylinder and valve service, the 40 um standard grade is usually sufficient; the two grades are ordered under their own codes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.