verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-08 Combination Unit (GFC30008F1)

The AirTAC AirTAC GFC300-08 Combination Unit (GFC30008F1) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$67.25 $72.60Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC300-08 Combination Unit (GFC30008F1)

The GFC30008F1 is a two-piece air-treatment set from AirTAC's G series: a size 300 filter regulator paired with a size 300 lubricator on 1/4 in PT ports. The filter stage strips water and 40 um particulate into a polycarbonate bowl with a differential-pressure drain, the regulator holds downstream pressure anywhere in its 0.15-0.9 MPa (20-130 psi) adjust range, and the lubricator meters oil mist to downstream tooling. Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing. This configuration specifies the square gauge reading in MPa.

This is a genuine AirTAC part. The G two-piece sets are offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options include manual or automatic drains, a 5 um element (code W), round external gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads in place of PT. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.

AirTAC GFC300-08 Combination Unit (GFC30008F1) Technical Specifications

ModelAirTAC GFC300-08 Combination Unit (GFC30008F1)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-08 Combination Unit (GFC30008F1)

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-08 Combination Unit (GFC30008F1) Is Used

build

Air nailers and staplers on a truss fabrication bench

Supplies the nail guns and staplers on a timber truss and frame bench. The filter keeps moisture and debris out of the tool air, the regulator pins the pressure for consistent fastener depth, and the lubricator feeds the driver mechanisms.

conveyor_belt

Pusher and gate cylinders on a food-grade conveying line

Runs the reject pushers and lane gates along a dry-goods packaging conveyor. Clean, regulated, oil-misted air keeps the compact cylinders cycling quickly and evenly through every shift.

engineering

Pneumatic presses at a small stamping and riveting cell

Feeds the bench-mounted pneumatic presses and riveters in a light metalworking cell. The regulator sets the press force repeatably, the 40 um element protects the cylinder seals, and the lubricator reduces wear under continuous duty.

Is the AirTAC GFC300-08 Combination Unit (GFC30008F1) the Right Set?

Size 300 with 1/4 in PT ports is the mid step of the G range; move to size 400 if your demand runs near the limit of a 300. Drain choice: differential-pressure (this code, standard), automatic (A) for unattended drainage, or manual (M) - manual-drain versions widen the regulator adjust range to 0.05-0.9 MPa (7-130 psi). Element grade is 40 um standard or 5 um with code W. This code selects the square MPa gauge; round external gauges in psi or bar scales are ordered under their own codes. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options; a mounting bracket is optional. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

AirTAC GFC300-08 Combination Unit (GFC30008F1) FAQ

AirTAC publishes G-series flow as performance curves, not as a single rated figure, so no rated number is quoted here. Send us your working pressure and air demand and we will confirm the sizing from the datasheet curve on request before you order.

G units with a regulator can carry an embedded square gauge or an external round gauge, each in MPa, psi or bar scales. This code (F1) specifies the square gauge reading in MPa; round psi or bar versions are ordered under codes such as C2 and C3, so choose the scale your maintenance team reads.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC300-08 Combination Unit (GFC30008F1)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC30008F1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.