verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-08 Combination Unit (GFC30008MC1K)

The AirTAC AirTAC GFC300-08 Combination Unit (GFC30008MC1K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$78.60 $84.23Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC300-08 Combination Unit (GFC30008MC1K)

The AirTAC GFC series is a two-unit air preparation set: a filter-regulator plus a lubricator supplied as a matched pair, so one order covers filtration, pressure regulation and oil-mist lubrication. This GFC30008MC1K is the size 300 set with PT1/4 ports, a manual drain on the filter-regulator bowl, the standard 40 um filter element, an external round gauge reading in MPa, and a built-in reverse (check) valve that holds downstream pressure when the upstream supply is removed. Maximum working pressure is 1.0 MPa (145 psi); with this manual-drain configuration the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi); operating temperature is -5 to 70 C (non-freezing). The bowls on this size 300 set are polycarbonate (PC).

This is a genuine AirTAC part for the US market. The GFC family is available in sizes 200, 300, 400 and 600 with ports from 1/8 in. to 1 in., ordered with your choice of drain type, 40 um or 5 um filtration, gauge and scale, reverse valve, and G (BSPP) or NPT threads instead of the PT standard. Flow for the G series is published as curves rather than one rated figure, so ask us and we will confirm the datasheet flow data for your application on request.

AirTAC GFC300-08 Combination Unit (GFC30008MC1K) Technical Specifications

ModelAirTAC GFC300-08 Combination Unit (GFC30008MC1K)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-08 Combination Unit (GFC30008MC1K)

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-08 Combination Unit (GFC30008MC1K) Is Used

factory

Paint line supply drop

Mounted at the drop feeding a spray booth's air logic panel, this set removes water and particulate, holds a steady regulated pressure for the spray valves, and meters oil mist to keep the actuators moving smoothly through a full shift.

conveyor_belt

Cartoning machine air supply

On a cartoner's pneumatic cylinders and glue-head valves, the filter-regulator cleans and stabilises the supply while the lubricator feeds the valve spools, and the check valve keeps the circuit charged during brief upstream interruptions.

precision_manufacturing

CNC fixture clamping circuit

Feeding the clamp cylinders on a machining centre fixture, the unit delivers filtered, regulated air at a set pressure with a visible gauge reading, while lubrication protects the clamping valves over repeated cycles.

Is the AirTAC GFC300-08 Combination Unit (GFC30008MC1K) the Right Set?

Size 300 with 1/4 in. PT ports is the mid step of the G-series range; match the port and size step to the flow your line needs, moving to size 400 (1/2 in. ports) if demand sits near the top of the size 300 curves. The manual drain here means an operator opens the bowl drain periodically - pick the automatic-drain version for unattended installations. Filtration is the standard 40 um element; add the W suffix for 5 um when downstream valves and cylinders need finer protection. The gauge is the external round type with an MPa scale (a psi scale is offered). Threads are PT as standard; order G (BSPP) or NPT to match your piping, and choose the bracket option if you panel-mount. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

AirTAC GFC300-08 Combination Unit (GFC30008MC1K) FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated number, so no rated flow figure is quoted here. Tell us your required flow and working pressure and we will confirm the datasheet curves for this 1/4 in. set against your application on request.

K means a reverse (check) valve is fitted to the filter-regulator section: if the upstream supply is shut off, the valve holds pressure downstream so regulated circuits and cylinders do not dump back toward the supply. Sets without the K are ordered without this function.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC300-08 Combination Unit (GFC30008MC1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC30008MC1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.