verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-08 Combination Unit (GFC30008MF1W)

The AirTAC AirTAC GFC300-08 Combination Unit (GFC30008MF1W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$67.25 $72.60Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC300-08 Combination Unit (GFC30008MF1W)

The AirTAC GFC series is a two-piece air preparation set: a filter-regulator and a lubricator mounted together, so one code covers filtration, pressure regulation and oil-mist lubrication. This GFC300 unit is made for 1/4 in PT piping and takes compressed air at up to 1.0 MPa (145 psi). The manual drain means you bleed condensate from the polycarbonate bowls by hand, the W element filters to 5 um instead of the standard 40 um, and the built-in square gauge reads set pressure in MPa. The regulator on the manual-drain version covers a setting range of 0.05-0.9 MPa (7-130 psi).

This is a genuine AirTAC part. The G series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in; PT is the standard thread and G (BSPP) or NPT are catalogue options to order. At 300 size the bowls are polycarbonate, and service is -5 to 70 C non-freezing. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and the datasheet for your application.

AirTAC GFC300-08 Combination Unit (GFC30008MF1W) Technical Specifications

ModelAirTAC GFC300-08 Combination Unit (GFC30008MF1W)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-08 Combination Unit (GFC30008MF1W)

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-08 Combination Unit (GFC30008MF1W) Is Used

precision_manufacturing

Bench pneumatic press

Sets the working pressure on a small bench press cylinder and feeds it oil-misted air, with the 5 um element keeping the valve seat clean.

view_module

Packaging machine actuators

Supplies the gripper and clamp cylinders on a cartoning or case-packing line with regulated, lubricated air from a single 1/4 in drop.

handyman

Assembly cell hand tools

Prepares air for impact drivers and nutrunners at an assembly station, where the lubricator keeps the tool motor oiled during shifts.

Is the AirTAC GFC300-08 Combination Unit (GFC30008MF1W) the Right Set?

Pick 300 size with the 1/4 in port when your line sits in the mid-range of the G series; step up to 400/600 or down to 200 to match piping and demand. Manual drain suits attended installations where operators drain the bowls during routine checks; automatic or differential-pressure drain codes cover unattended duty. This W code carries the finer 5 um element - choose it when downstream devices need cleaner air than the standard 40 um element gives. Gauge scale is MPa here; psi and bar scales are other catalogue codes. Flow is published as curves, not a single rating, so send us your air demand and we will confirm the sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

AirTAC GFC300-08 Combination Unit (GFC30008MF1W) FAQ

AirTAC publishes flow for this series as characteristic curves, not as a single rated number, so there is no honest one-line figure to quote. Tell us your required flow and working pressure and we will confirm the sizing against the datasheet on request before you order.

M means the bowls are drained by hand, which suits attended installations; automatic (A) or differential-pressure (blank) drain versions exist for unattended duty. The trailing W selects the finer 5 um filter element; dropping the W gives the standard 40 um element in the same set.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC300-08 Combination Unit (GFC30008MF1W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC30008MF1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.