The AirTAC AirTAC GFC300-10 Combination Unit (GFC30010AC1K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC30010AC1K is a two-piece AirTAC G-series set combining a filter regulator and a lubricator, with a reverse (check) valve fitted so flow cannot run backwards through the set. This size-300 unit filters to the standard 40 um grade, has PT3/8 ports, an automatic drain (A) on the filter bowl and an external round gauge scaled in MPa. With the automatic drain, the regulator adjusts 0.15-0.9 MPa (20-130 psi).
It is a genuine AirTAC part for compressed air, rated to a maximum working pressure of 1.0 MPa (145 psi) and -5 to 70 C (non-freezing). The same set is available without the check valve, and the GFC family spans sizes 200, 300, 400 and 600 in 1/8 to 1 inch ports with drain, filter-grade, gauge and thread options. Flow is published as curves rather than a single rated figure, so we confirm datasheet figures on request.
| Model | AirTAC GFC300-10 Combination Unit (GFC30010AC1K) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT3/8" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-10 |
| Build order | Filter regulator first, lubricator last |
Protects a branch tapped off a shared plant air main that feeds directional control valves; the fitted reverse (check) valve blocks backflow from downstream toward the set.
Feeds the hold-down cylinders of a small pneumatic press with filtered, regulated, lubricated air, while the external MPa gauge supports quick pressure verification during setup.
Supplies a laboratory test rig's air actuators; the 40 um element and automatic drain keep particulate and condensate out of the rig between test runs.
The K suffix is the only difference from the GFC30010AC1: it adds a reverse (check) valve, useful when a set feeds a branch where downstream backflow is possible. Otherwise the decodable choices are the same - sizes 200 to 600 with 1/8 to 1 inch ports, the 40 um standard element versus the 5 um (W) option, and automatic, manual or differential-pressure drains. Flow is published as curves, so ask us to confirm sizing against your application before ordering.
The C1 suffix specifies the external round gauge in MPa, with psi and bar scales as catalogue alternatives. PT is the standard thread; G (BSPP) and NPT are orderable options.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.
No single rated flow figure is quoted, because AirTAC publishes G-series flow as performance curves rather than one number. Send us your application details and we will confirm the sizing against the datasheet on request.
K fits a reverse (check) valve in the set; without it the GFC30010AC1 is otherwise identical - same 40 um filter, automatic drain, PT3/8 ports and external MPa gauge. The check valve prevents reverse flow through the set, and the regulation range stays 0.15-0.9 MPa (20-130 psi) with the automatic drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.