The AirTAC AirTAC GFC300-10 Combination Unit (GFC30010C1K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit air treatment set: a filter regulator plus a separate lubricator, combining filtration, regulation and oil-mist lubrication. This GFC300-10C1K is the 300 size with PT3/8 ports, a differential-pressure drain, standard 40 um filtration, the round external MPa gauge, and the K option fitting a reverse/check valve in the regulator section.
This is a genuine AirTAC part for compressed air only. The GFC family spans 200, 300, 400 and 600 sizes with drain, filtration-grade, gauge and thread options; PT, G and NPT threads are catalogue choices. Flow is published as curves rather than a single rating, so we confirm datasheet figures and sizing on request.
| Model | AirTAC GFC300-10 Combination Unit (GFC30010C1K) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT3/8" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-10 |
| Build order | Filter regulator first, lubricator last |
A two-unit set feeding gripper and tool-changer circuits on a robot cell, with the fitted check valve helping hold the regulated circuit against upstream supply dips.
Filtering, regulating and lubricating air on a workshop rig servicing trailer air systems, where the check valve prevents backflow toward the supply side.
Conditioning air to diverter and stopper cylinders on a bottling conveyor, keeping the actuation circuit clean, lubricated and protected from reverse flow.
Choose size (200/300/400/600) to match your port and flow needs - the 300 with 3/8 ports covers mid-range circuits. This variant carries the K suffix, meaning a reverse/check valve is fitted in the regulator; order the non-K code if you do not want it. Drain is differential-pressure here (automatic A or manual M are orderable), filtration is the standard 40 um (W gives 5 um), and the C1 suffix specifies the round external gauge with MPa scale. Thread is PT standard, with G and NPT as order options.
Because flow is published only as curves, ask us to confirm this unit's sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.
AirTAC publishes flow for this series as curves, not as a single rated number, so quoting one figure would be guesswork. Send us your line pressure and consumption and we will confirm the correct size from the datasheet before you order.
K means a reverse/check valve is fitted in the regulator section, allowing flow in one direction only through the unit. The rest of the decode is unchanged: 300 size, PT3/8 ports, differential-pressure drain, 40 um filtration, round external gauge with MPa scale, plus the lubricator that makes GFC a two-unit set.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.