AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010F1K)

The AirTAC AirTAC GFC300-10 Combination Unit (GFC30010F1K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$78.60 $84.23Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC300-10 Combination Unit (GFC30010F1K)

The AirTAC GFC series is a two-unit set: a filter-regulator that removes water and particulate from compressed air and holds downstream pressure, plus a lubricator that meters oil mist to downstream tools and cylinders. This GFC30010F1K is the size 300 frame with PT 3/8 in ports, a standard 40 um element, and a polycarbonate bowl with differential-pressure drain on the filter-regulator section. The embedded square gauge is scaled in MPa, and the K suffix adds a reverse (check) valve in the regulator section so downstream pressure is held if the upstream supply dips. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts 0.15-0.9 MPa (20-130 psi) with this drain type, and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The G-series covers sizes 200, 300, 400 and 600, with options including a 5 um element, automatic or manual drains, NPT or G (BSPP) threads, other gauge scales, and versions without the check valve or gauge. AirTAC publishes flow as curves rather than a single rated figure, so we will confirm the datasheet figures for your duty on request.

AirTAC GFC300-10 Combination Unit (GFC30010F1K) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010F1K)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010F1K)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010F1K) Is Used

bolt

Weld-cell clamp fixtures

On weld-cell clamp fixtures, the K check valve holds the regulated downstream pressure if the main header sags, so clamp cylinders keep the part located while the filter-regulator and lubricator condition the supply.

handyman

Maintenance shop tool reels

Feeding hose-reel outlets in a maintenance shop, the set delivers clean, regulated, oil-misted air to impact wrenches and ratchets, and the check valve keeps the reel circuit charged during upstream switching.

speed

High-cycle sorting gates

On a sorting line's rapid-cycling gate cylinders, the filter-regulator holds consistent set pressure for repeatable gate timing while the check valve protects the circuit from upstream pressure dips, and the lubricator conditions the air.

Is the AirTAC GFC300-10 Combination Unit (GFC30010F1K) the Right Set?

Pick this F1K version when a supply dip must not bleed your downstream circuit: the K-fitted check valve holds the regulated side while you fix the upstream side, which matters on clamping and holding duties. Size 300 with 3/8 in PT ports is the mid step (200/300/400/600); we can check the published flow curves against your demand before you order. Drain is differential-pressure as standard here, with automatic and manual variants available; the 40 um element is standard and the W option gives 5 um. The embedded square gauge reads MPa; round psi and bar gauges and a no-gauge variant exist. PT thread is standard, with G (BSPP) and NPT as catalogue options, and a bracket is available.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010F1K) FAQ

AirTAC publishes G-series flow as performance curves, not as a single rated figure, so we do not quote one number here. Give us your line pressure and the demand of the actuators or tools downstream, and we will confirm the sizing from the datasheet on request before you order.

K means a reverse (check) valve is fitted in the regulator section: if upstream pressure falls away, the valve holds the pressure already set downstream. Otherwise the unit is the standard GFC300 two-unit set - 3/8 in PT ports, 40 um element, differential-pressure drain, square MPa gauge - and the same family is offered without the check valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010F1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC30010F1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.