AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010F3K)

The AirTAC AirTAC GFC300-10 Combination Unit (GFC30010F3K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$78.60 $84.23Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC300-10 Combination Unit (GFC30010F3K)

GFC30010F3K is AirTAC's G-series two-unit air preparation set for compressed air: a filter-regulator plus a separately mounted lubricator, so one supply connection removes water and particulate, holds a set downstream pressure and adds oil mist for the cylinders and tools that follow. This build carries the standard 40 um element, the differential-pressure drain, an embedded square gauge scaled in bar, and a reverse (check) valve fitted on the regulator. Ports are PT3/8 in the 300 size.

It is a genuine AirTAC part. The G-series runs from size 200 to 600, with PT, G (BSPP) or NPT threads, 40 um or 5 um filtration, differential-pressure, automatic or manual drains, MPa, psi or bar gauge scales, and an optional check valve, so the same function is available with a larger or smaller port. Flow is published as curves rather than a single rating; ask us and we will confirm sizing and datasheet figures for your application on request.

AirTAC GFC300-10 Combination Unit (GFC30010F3K) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010F3K)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, bar scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010F3K)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010F3K) Is Used

precision_manufacturing

Pneumatic clamping on machining fixtures

Feeds and protects clamp cylinders on a CNC fixture: filtered, regulated and lubricated air to the clamps, with the fitted check valve helping hold the clamped circuit if the main supply dips mid-cycle.

conveyor_belt

Divert cylinders on a carton packaging line

Mounted at the drop feeding the pusher and diverter cylinders on a carton conveyor, so the actuation air stays dry, held at set pressure and oiled for long cylinder life.

factory

Assembly bench air drop for hand tools

Installed at a plant air drop serving impact drivers and ratchets on an assembly bench: the filter-regulator cleans and steadies the supply while the lubricator mists oil into the tool air.

Is the AirTAC GFC300-10 Combination Unit (GFC30010F3K) the Right Set?

Start from port and flow: the 300 size with PT3/8 ports sits mid-range in the G-series; step to 200 for compact lines or to 400/600 where the header uses larger ports. This code fixes the standard 40 um element, the differential-pressure drain (automatic and manual drains are separate codes), the bar-scale square gauge and the fitted check valve; psi or MPa gauge scales and a build without the check valve are orderable. The thread is PT as the standard; G (BSPP) and NPT are catalogue options to order. The set runs on compressed air only, -5 to 70 C, non-freezing.

Then the honest routing: AirTAC publishes flow for this family as curves across pressure, not as one rated figure, so ask us to check the curve for the GFC30010F3K against your demand and pressure before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010F3K) FAQ

AirTAC publishes G-series flow as curves across working pressure, not as one rated number, so we do not quote a single figure. Tell us your line pressure and air demand and we will confirm sizing and the datasheet figures on request.

It marks a reverse (check) valve fitted on the regulator section, which helps hold downstream pressure if the upstream supply drops. The same set without the K is the standard build; drain type, filter grade and gauge scale are all separate orderable choices.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010F3K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC30010F3K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.